(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 9:00 19/4/2026 to 7:00 (MYT) 20/4/2026. We apologize for the inconvenience.
  • [Notice] Japan & China Golden Week holidays will start from 29 April to 6 May 2026. Kindly expect longer response from suppliers and possible delivery delay due to high volume of shipments after holiday. Early order placement is recommended. More details
  • [Announcement] MISUMI Malaysia website new user interface. Clearer navigation, easy product search and more. Explore now! May contact us at (60) 3 7890 6399 for any inquiries.

High EMI Countermeasures Cable

High EMI Countermeasures Cable

Noise resistant cable and hood used

  • PLC
  • EMI Countermeasure
  • Pressure Welding
  • Gold Plated
  • DI/O

● Cables that feature the Hirose Electric Original half pitch connector DX31 Series. Misumi original 2-layer shield acting as a perfect noise countermeasure.
● It can be coupled with the DX30 half pitch connector (manufactured by Hirose Electric).


· Please note that IEEE1284 half pitch connector cables have different product standards. Please be careful.
· The shield is connected to the hood.
· The connector model WRD 31 does not support 100-core.

Wiring and Wire Color Page
Component Page

PDF

Specifications

High EMI Countermeasures Cable:Related Image

Connector TypeShape Specification TypeOutline Image Drawing (Unit: mm)Number of CoresSpecified Length (m)
WRD31
One-touch Lock
with Hood
100-core unavailable


WSD31
M3 Screw Lock
with Hood

Hirose Electric Co., Ltd







Cable
NA28WSH

Misumi Original
P
(Male)
High EMI Countermeasures Cable:Related Image200.2

~

50


Can be specified by 0.1m
increments
28
36
50
80
100
PP
(Male /Male)
High EMI Countermeasures Cable:Related Image20
28
36
50
80
100
PY
(Male / Y Terminal)
With Pin No. Insertion
Mark Tube
High EMI Countermeasures Cable:Related Image20
28
36
50
80
100
PT
(Male / Loose Wires)
With Pin No. Insertion
Mark Tube
High EMI Countermeasures Cable:Related Image20
28
36
50
80
100

Specified Length (m)~ 0.91 ~ 44.1 ~ 50
Tolerance+20mm+50mm+ 3% of Specified Length
* The tolerance of the specified length is as described above.
Part Number
WSD31-PP-100-[0.2-50/0.1]
WSD31-PT-100-[0.2-50/0.1]
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipCN2 Specified Length
(m)

-

1 Piece(s) 4 Day(s) or more Male0.2 ~ 50

-

1 Piece(s) 4 Day(s) or more Discrete wire0.2 ~ 50

Loading...

  1. 1

Overview

DX Series connectors are EMI-countermeasure compact, high density interface connectors designed to have 1.27 mm pitch between contacts to support the densification and higher-volume installation involved in the miniaturizing of electronic devices.

● Effective for miniaturizing electronics as the pitch between contacts is 1.27 mm.
● Effective against prying and has soft insertion / extraction performance as the terminal structure is ribbon shaped.
● Structured so that the shell side always touches before the contact when coupling in order to prevent damage of the set due to static electricity.
● Secure noise protection can be expected as the cover case and the receptacle shell are robust and made with zinc alloy die-casting which has good shielding effect against electromagnetic waves.

Specifications

Main Performance
Current Capacity 0.5 A
Rated Voltage 125 VAC
Insulation Resistance 250 MΩ or more at 100 VDC
Contact Resistance 50 mΩ or less at 100 mA DC
Withstand Voltage 300 VAC r.m.s. 1 min
Main Materials Used
Plug Case Die-cast Zinc Silver Coating
Receptacle Case Die-cast Zinc Nickel-plated
Insulator PBT Resin, or equivalent or higher * Black
Male Terminal Copper Alloy Partially Gold Plated
Female Terminal Copper Alloy Partially Gold Plated

Dimensions (Unit: mm)

Connector Dimensions

Number of Cores A B C
20 11.43 19.18 17.2
28 16.51 21.26 17.2
36 21.59 29.34 17.2
50 30.48 38.23 17.2
68 41.91 49.66 17.2
80 49.53 57.28 17.2
100 62.23 69.98 18.2

Hood Dimensions

Number of Cores A B C D E
20 34.2 32 M3 x 0.5 30 32.5
28 39.28 32 M3 x 0.5 35.08 32.5
36 44.36 32 M3 x 0.5 40.16 32.5
50 53.25 32 M3 x 0.5 49.05 32.5
68 64.68 32 M3 x 0.5 60.48 32.5
80 72.3 32 M3 x 0.5 68.1 32.5
100 85 38.9 M2.6 x 0.45 - -

Contact Arrangement Diagram

Basic Information

Connector type DX31 Connector manufacturer Hirose Electric Group Connector Shape Straight
Machining Method Pressure welding Cable shape Circular Hood EMI-compatible metal
Hood screw M3 threadlock CN1 Male Number Of Cores 100
Cable rated voltage(V) 30 Shield 2 Layer Cable standard (UL/CSA) UL
Cable color Navy Twisted pair Included AWG 28

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7960 8499 / FAX:(60) 3 7960 7499
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)