(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 9:00 19/4/2026 to 7:00 (MYT) 20/4/2026. We apologize for the inconvenience.
  • [Notice] Japan & China Golden Week holidays will start from 29 April to 6 May 2026. Kindly expect longer response from suppliers and possible delivery delay due to high volume of shipments after holiday. Early order placement is recommended. More details
  • [Announcement] MISUMI Malaysia website new user interface. Clearer navigation, easy product search and more. Explore now! May contact us at (60) 3 7890 6399 for any inquiries.

UL3385 UL Supported Non-Halogen Tubes (UL3385-24-R-50)

UL3385 UL Supported Non-Halogen Tubes UL3385-24-R-50

Click this image to zoom it.

Move the mouse over the image to zoom

300 V UL1007 economical model single-core wire

  • CSA
  • VW-1
  • ULAWM
  • Heat-Resistant
  • Strand Wire
  • 300 V

● Cables for internal wiring of various electric and electronic devices.
● Halogen-free model cable with UL1007 single-core wire.
● Passed VW-1 (UL), FT1 (CSA), and F-flame retardancy tests.

· Be careful not to confuse total length and quantity when ordering.
· Because non-halogen material uses a polyolefin-based material with metal hydrate flame retardant admixture, the surface may turn white (chlorosis) when rubbed strongly or scratched against corners of piping, etc, but the electrical properties and performance of the cable will not be affected.
· It has lighter blue (BE) color compared to other cables.
· This product is compatible with "UL Traceability Program / Processed Wire." (c-UL is not compatible)

Electrical Appliance and Material Safety Law certificate has not been obtained.

Operating Temperature Range0 – 105°C
Standard AcquiredULAWM3385
Bending RadiusFinished Outer Diameter x 8 (Fixed Part)

PDF

Part Number

Configured Part Number is shown.

UL3385-24-R-50

Specifications

UL3385 UL Supported Non-Halogen Tubes:Related Image

Model NumberAWG
Size
Color
UL338524* (0.2mm2)W (White)
BK (Black)
R (Red)
BE (Blue)
Y (Yellow)
GN (Green)
22* (0.3mm2)
20* (0.5mm2)
18* (0.75mm2)
16* (1.25mm2)
* (~ mm2) is to be used only as an estimated section area. Refer to the comparison table on >>Click here for details.


Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
* For the latest information regarding standard unit price, quantity slide unit price, shipment days, etc., refer to the Misumi VONA e-catalog.

More Information

Model NumberAWG
Size
ColorTotal Length
(m)
ConductorInsulator
Thickness
(mm)
Finished
Outer Diameter
Approx. (mm)
Conductor Resistance
Ω / km (20°C)
Insulation Properties
MΩkm
(15.6°C)
Test Voltage
V / Min
Allowable Current
A (30 °C)
Approximate
Mass
kg/km
Structure
(Strands / mm)
Outer Diameter
(mm)
UL338524* (0.2mm2)W (White)
BK (Black)
R (Red)
BE (Blue)
Y (Yellow)
GN (Green)
10
/
50
/
100
/
304
11/0.160.620.411.4388.9 or less10 or more20007.23.9
22* (0.3mm2)17/0.160.761.5857.5 or less9.45.38
20* (0.5mm2)26/0.160.951.7737.6 or less12.37.4
18* (0.75mm2)41/0.161.190.422.0223.8 or less16.610.8
16* (1.25mm2)54/0.181.532.3714.3 or less23.116.5
* (~ mm2) is to be used only as an estimated section area. Refer to the comparison table on >>Click here for details.
* For the outer diameter size of cables, wire sheath (coat), etc., refer to "Finished Outer Diameter" in the table above.

UL3385 UL Supported Non-Halogen Tubes:Related Image

Current Reduction Factor
Ambient Temperature (°C)35455565758595105
Current Reduction Factor0.960.890.810.730.630.510.360.25
Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) AWG24: Allowable current value when the ambient temperature is 45°C
7.2 x 0.89 = 6.41 (A)

Package Type
Vinyl Bag: The wires are wound into a bundle and tied with rope or vinyl string and then packed in a vinyl bag.
Case: The wires are wound into a bundle and tied with string etc., and packed in a case (cardboard box).
Model NumberAWG SizeTotal Length
304m100m50m10m
UL338524* (0.2mm2)Vinyl Bag (Case)Vinyl Bag (Case)Vinyl Bag (Case)Vinyl Bag (Case)
22* (0.3mm2)Vinyl Bag (Case)Vinyl Bag (Case)Vinyl Bag (Case)Vinyl Bag (Case)
20* (0.5mm2)Vinyl Bag (Case)Vinyl Bag (Case)Vinyl Bag (Case)Vinyl Bag (Case)
18* (0.75mm2)Vinyl Bag (Case)Vinyl Bag (Case)Vinyl Bag (Case)Vinyl Bag (Case)
16* (1.25mm2)Vinyl Bag (Case)Vinyl Bag (Case)Vinyl Bag (Case)Vinyl Bag (Case)
* (~ mm2) is to be used only as an estimated section area. Refer to the comparison table on >>Click here for details.
Part Number
UL3385-24-R-50
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOverall Length
(m)
Conductor Cross Section
(mm2)
AWG size
(AWG)
Finished outer diameter
(mm)
Sheath (outer coating) color

MYR 196.67

1 Piece(s) Quote 500.2241.43Red

Loading...

  1. 1

Basic Information

Number Of Cores(Core) 1 Rated Voltage 300V Shield None
Representative Standard UL / CSA(c-UL)

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7960 8499 / FAX:(60) 3 7960 7499
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)