The 2-circuit limit switch with variety of models that can be selected matching to the usage environment and application.
[Features]
· Circuit will break without fail by using 2-circuit double-break.
· Structure suitable to IP67 due to O ring and/or cover seal.
· Overseas approval corresponding to the machines for export approved by UL, CSA, TUV, EN/IEC, CCC.
· Most suitable to machines for export.
· Optimum high accuracy type in controlling the position is available in all types.
· Movement till operation is less (about 5°) but repeatability is two times of standard type
Japanese Only
Part Number
Configured Part Number is shown.
WLCA12-RP-N
| Part Number |
|---|
| WLCA12-RP-N |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Detector Shape | Environment | Plunger Shape Type | Boot Seal | Roller Lever Shape Type | Rod Shape Type | Operating Temperature Range (°C) | Acquired Standards | Protection Structure | Force Required for Push Side O.F. (N) | Motion to Switching P.T. (mm) | Angle to Switching P.T (deg) | Max. Stroke T.T (mm) | Contact Type | Mechanical Life (10,000 times) | Mechanical Operation Frequency (times/min or Less) | Rated Operating Voltage (V) | Rated Conductance Current (A) | Main Body External Dimension, Width W (mm) | Main Body External Dimension, Height H (mm) | Main Body External Dimension, Length L (mm) | Lever Length R (mm) | Cable Specifications | Detector element details | Indicator Light | Movement After the Operation OT (mm) | Operating Position OP (mm) | Conduit size | Specification of Terminal | Cord / cable length (m) | Details Type | O.D. | Function | Mounting system | Direction of Operation | Roller position | Contact format | Built-in Switch Specification | Wiring Specifications | Lever Tightening Specification | AC Rated Voltage | DC Rated Voltage | AC Electrical Rating details | DC Electrical Rating details | Head Material | Specifications | Application | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 330.17 | 1 Piece(s) | 1 Day(s) | Roller Lever Type (rotation) | Standard / Outdoor Corrosion Resistance / Hydrogen Gas | - | Presence | Variable Roller Levers | - | -10~80 | UL / GB(CCC) / CQC / CSA | IP67 | 13.34 | - | 15±5 | - | 2-circuit Double-break | 1500 | 120 | AC100/125V / AC240/250V / More than AC300V | 10 | 40±0.7 | 67 | 94.1 | 25-89 | - | Stainless Steel Type Sintering Roller φ17.5×7 | No | - | - | G1/2 | Ground terminal not included | - | Environmentally tolerant type, corrosion-resistant type | φ17.5×7 | - | 4-direction (front / rear / side) mounting | Snap action, single sided operation supported | - | 1a1b | - | - | - | - | - | - | - | - | - | - | - |
Loading...
| Main Body Size | Standard |
|---|
Please check the type/dimensions/specifications of the part WLCA12-RP-N in the Two-circuit limit switch WL series.
| Part Number |
|---|
| WL-6H1100(WLCA2-2N HEAD,LEVER) |
| WL-9H100(WLNJ HEAD,LEVER) |
| WL-9H200(WLNJ30 HEAD,LEVER) |
| WLCA2 |
| WLCA2-2-N |
| WLCA2-2TH |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Detector Shape | Environment | Plunger Shape Type | Boot Seal | Roller Lever Shape Type | Rod Shape Type | Operating Temperature Range (°C) | Acquired Standards | Protection Structure | Force Required for Push Side O.F. (N) | Motion to Switching P.T. (mm) | Angle to Switching P.T (deg) | Max. Stroke T.T (mm) | Contact Type | Mechanical Life (10,000 times) | Mechanical Operation Frequency (times/min or Less) | Rated Operating Voltage (V) | Rated Conductance Current (A) | Main Body External Dimension, Width W (mm) | Main Body External Dimension, Height H (mm) | Main Body External Dimension, Length L (mm) | Lever Length R (mm) | Cable Specifications | Detector element details | Indicator Light | Movement After the Operation OT (mm) | Operating Position OP (mm) | Conduit size | Specification of Terminal | Cord / cable length (m) | Details Type | O.D. | Function | Mounting system | Direction of Operation | Roller position | Contact format | Built-in Switch Specification | Wiring Specifications | Lever Tightening Specification | AC Rated Voltage | DC Rated Voltage | AC Electrical Rating details | DC Electrical Rating details | Head Material | Specifications | Application | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 88.06 | 1 Piece(s) | 3 Day(s) | - | Standard | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Roller lever type | - | - | - | - | - | - | Head only parts set type, for WLCA2-2N | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | For WLCA2-2N | Stainless sintered roller | ||
MYR 62.17 | 1 Piece(s) | 3 Day(s) | - | Standard | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Flexible rod type | - | - | - | - | - | - | Head only parts set type, for WLNJ | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | For WLNJ | Coil spring | ||
MYR 62.17 | 1 Piece(s) | 3 Day(s) | - | Standard | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Flexible rod type | - | - | - | - | - | - | Head only parts set type, for WLNJ30 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | For WLNJ-30 | Coil spring | ||
MYR 166.42 | 1 Piece(s) | 5 Day(s) or more | Roller Lever Type (rotation) | Standard | - | No | Standard | - | -10~80 | UL / CSA / GB(CCC) / CQC | IP67 | 13.34 | - | 15±5 | - | 2-circuit Double-break | 1500 | 120 | DC250V / DC125V / AC100/125V / DC30V or Less / More than AC300V / AC240/250V | 10 | 40±0.7 | 60 | 94.1 | 38 | - | Stainless Steel Type Sintering Roller φ17.5×7 | No | - | - | G1/2 | Ground terminal not included | - | General standard type, reference type, general load type | φ17.5×7 | - | Bi-directional (front / back) mounting | Snap Action | - | 1a1b | - | - | - | - | - | - | - | - | - | - | - | ||
MYR 205.12 | 1 Piece(s) | 1 Day(s) | Roller lever type | Standard | - | - | - | - | -10~80 | UL / CSA | IP67 | - | 25±5° | - | - | - | 1500 | 120 | - | - | - | - | - | - | - | Roller lever type | No | - | - | G1/2 | Ground terminal not included | - | General operating display type, standard type | - | - | - | - | - | - | General built-in switch | Screw terminal type | Standard (hexagon socket head cap screw) | 125 / 250 / 500 | 8 / 14 / 30 / 125 / 250 | 125 V AC, 250 V, 500 V (10 A) | 8 V DC, 14 V (10 A) / 30 V (6 A) / 125 V (0.8 A) / 250 V (0.4 A) | Stainless sintered roller | General load/micro-load | - | R38 mm | ||
MYR 264.06 | 1 Piece(s) | 1 Day(s) | Roller Lever Type (rotation) | Standard / Heat Resistant | - | No | Standard | - | 5~120 | UL / CSA / GB(CCC) / CQC | IP67 | 8.83 | - | 25±5 | - | 2-circuit Double-break | 1500 | 120 | DC250V / DC125V / AC100/125V / DC30V or Less / More than AC300V / AC240/250V | 10 | 40±0.7 | 60 | 94.1 | 38 | - | Stainless steel-based sintered roller φ17.5 × 7 | No | - | - | G1/2 | Ground terminal not included | - | Environmentally tolerant type, overtravel type 90° (-2 type) heat-resistant type | φ17.5×7 | - | 4-direction (front / rear / side) mounting | Snap action, single sided operation supported | - | 1a1b | - | - | - | - | - | - | - | - | - | - | - |



![Standard type proximity sensor [E2E]](http://stg0-my.misumi-ec.com/linked/material/mech/OMR1/PHOTO/OMR1_221000398713.jpg?$product_recommend_b$)
OMRON
Standard Price : MYR 284.05-
Days to Ship : 1 Day(s) or more



OMRON
Standard Price : MYR 34.67-
Days to Ship : 1 Day(s) or more

![Photoelectric Sensors with built-in small amplifier [E3Z]](http://stg0-my.misumi-ec.com/linked/material/mech/OMR1/PHOTO/OMR1_221000398342.jpg?$product_recommend_b$)
OMRON
Standard Price : MYR 210.96-
Days to Ship : 1 Day(s)
How can we improve?