[Features]
· Quick response: valve response time of 5 ms, vacuum response time of 28 ms
· Energy-saving: 17% reduction in air consumption, 21% increase in vacuum pressure reached
· Compact and lightweight: 46 g
· Equipped with vacuum pressure switch; can copy up to 10 switches simultaneously
Part Number
Configured Part Number is shown.
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Additional Function | Ultimate Vacuum (kPa) | Air Consumption Flow Rate (l/min) | Vacuum Port Connecting Port Shape | Vacuum Port One-Touch Fitting Size | Air Supply Port Connecting Port Shape | Application | Performance | Suction Flow (l/min) | Nozzle Dia. | Exhaust specifications | Combination of supply valve and release valve | Rated voltage | Electrical entry | Output specifications | Unit specifications | Lead wire specifications | Body type | Options | Manual override |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 601.08 | 1 Piece(s) | 23 Day(s) or more | Filter | - | - | One-Touch Coupling | ø2 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / NA | 24 V DC | L-type plug connector with lead wire | Without vacuum pressure switch | - | - | Single unit (PV, PD common port, PV = PD) | Without options | Non-locking push type | ||
MYR 787.98 | 1 Piece(s) | 21 Day(s) | Filter | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / NA | 24 V DC | L-type plug connector with lead wire | Without vacuum pressure switch | - | - | Single unit (PV, PD common port, PV = PD) | Without options | Non-locking push type | ||
MYR 829.02 | 1 Piece(s) | 21 Day(s) | Filter | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / NA | 24 V DC | L-type plug connector with lead wire | Without vacuum pressure switch | - | - | Single unit (PV, PD common port, PV = PD) | With bracket for single unit (enclosed with the product for shipment without being assembled) | Non-locking push type | ||
MYR 1,256.55 | 1 Piece(s) | 17 Day(s) or more | Filter | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / NA | 24 V DC | L-type plug connector with lead wire | NPN 2 outputs (0 to -101 kPa) | With unit selection function | 2‑m lead wire with connector and connector cover | Single unit (PV, PD common port, PV = PD) | With bracket for single unit (enclosed with the product for shipment without being assembled) | Non-locking push type | ||
MYR 1,159.93 | 1 Piece(s) | 17 Day(s) or more | Filter | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / NA | 24 V DC | L-type plug connector with lead wire | NPN 2 outputs (0 to -101 kPa) | SI unit fixed | Without lead wire with connector | Single unit (PV, PD common port, PV = PD) | Without options | Non-locking push type | ||
MYR 1,190.70 | 1 Piece(s) | 17 Day(s) or more | Filter | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / NA | 24 V DC | L-type plug connector with lead wire | NPN 2 outputs (0 to -101 kPa) | SI unit fixed | Without lead wire with connector | Single unit (PV, PD common port, PV = PD) | With bracket for single unit (enclosed with the product for shipment without being assembled) | Non-locking push type | ||
MYR 1,269.69 | 1 Piece(s) | 23 Day(s) or more | Filter | - | - | One-Touch Fitting Elbow | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / NA | 24 V DC | L-type plug connector with lead wire | NPN 2 outputs (0 to -101 kPa) | SI unit fixed | 2‑m lead wire with connector and connector cover | Single unit (PV, PD common port, PV = PD) | With bracket for single unit (enclosed with the product for shipment without being assembled) | Non-locking push type | ||
MYR 646.15 | 1 Piece(s) | 17 Day(s) or more | Filter | - | - | One-Touch Fitting Elbow | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / NA | 24 V DC | L-type plug connector with lead wire | Without vacuum pressure switch | - | - | Single unit (PV, PD common port, PV = PD) | With bracket for single unit (enclosed with the product for shipment without being assembled) | Non-locking push type | ||
MYR 961.03 | 1 Piece(s) | 23 Day(s) or more | Filter | - | - | One-Touch Fitting Elbow | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / NA | 24 V DC | L-type plug connector, without connector | Output 1 to 5 V, accuracy ±2% F.S. or less (0 to -101 kPa) | - | Without lead wire with connector | Single unit (PV, PD common port, PV = PD) | Without options | Non-locking push type | ||
MYR 602.25 | 1 Piece(s) | 17 Day(s) or more | Filter | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / NA | 24 V DC | M-type plug connector with lead wire | Without vacuum pressure switch | - | - | Single unit (PV, PD common port, PV = PD) | Without options | Non-locking push type | ||
MYR 865.67 | 1 Piece(s) | 23 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | ø2 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | Without vacuum pressure switch | - | - | Single unit (PV, PD individual ports, PV ≠ PD) | Without options | Non-locking push type | ||
MYR 1,138.47 | 1 Piece(s) | 21 Day(s) | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | Without vacuum pressure switch | - | - | Single unit (PV, PD individual ports, PV ≠ PD) | Without options | Non-locking push type | ||
MYR 878.89 | 1 Piece(s) | 23 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | Without vacuum pressure switch | - | - | Single unit (PV, PD individual ports, PV ≠ PD) | Screwdriver operation type (vacuum break flow adjusting needle) | Non-locking push type | ||
MYR 1,454.12 | 1 Piece(s) | 17 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | NPN 2 outputs (0 to -101 kPa) | With unit selection function | Without lead wire with connector | Single unit (PV, PD individual ports, PV ≠ PD) | With bracket for single unit (enclosed with the product for shipment without being assembled) | Non-locking push type | ||
MYR 1,546.33 | 1 Piece(s) | 17 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Fitting Elbow | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | NPN 2 outputs (0 to -101 kPa) | With unit selection function | 2‑m lead wire with connector and connector cover | Single unit (PV, PD individual ports, PV ≠ PD) | With bracket for single unit (enclosed with the product for shipment without being assembled) / screwdriver operation type (vacuum break flow adjusting needle) | Non-locking push type | ||
MYR 1,423.43 | 1 Piece(s) | 17 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | NPN 2 outputs (0 to -101 kPa) | SI unit fixed | Without lead wire with connector | Single unit (PV, PD individual ports, PV ≠ PD) | Without options | Non-locking push type | ||
MYR 1,436.57 | 1 Piece(s) | 17 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Fitting Elbow | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | NPN 2 outputs (0 to -101 kPa) | SI unit fixed | Without lead wire with connector | Single unit (PV, PD individual ports, PV ≠ PD) | Without options | Non-locking push type | ||
MYR 2,008.10 | 1 Piece(s) | 21 Day(s) | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | NPN 2 outputs (0 to -101 kPa) | SI unit fixed | 2‑m lead wire with connector and connector cover | Single unit (PV, PD individual ports, PV ≠ PD) | With bracket for single unit (enclosed with the product for shipment without being assembled) | Non-locking push type | ||
MYR 1,502.43 | 1 Piece(s) | 17 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Fitting Elbow | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | NPN 2 outputs (0 to -101 kPa) | SI unit fixed | 2‑m lead wire with connector and connector cover | Single unit (PV, PD individual ports, PV ≠ PD) | Without options | Non-locking push type | ||
MYR 1,533.19 | 1 Piece(s) | 17 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Fitting Elbow | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | NPN 2 outputs (0 to -101 kPa) | SI unit fixed | 2‑m lead wire with connector and connector cover | Single unit (PV, PD individual ports, PV ≠ PD) | With bracket for single unit (enclosed with the product for shipment without being assembled) | Non-locking push type | ||
MYR 1,489.29 | 1 Piece(s) | 17 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | NPN 2 outputs (0 to -101 kPa) | With unit switching function (default: psi) | 2‑m lead wire with connector and connector cover | Single unit (PV, PD individual ports, PV ≠ PD) | Without options | Non-locking push type | ||
MYR 1,520.05 | 1 Piece(s) | 17 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | PNP 2 outputs (0 to -101 kPa) | SI unit fixed | 2‑m lead wire with connector and connector cover | Single unit (PV, PD individual ports, PV ≠ PD) | With bracket for single unit (enclosed with the product for shipment without being assembled) | Non-locking push type | ||
MYR 1,423.17 | 1 Piece(s) | 23 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | NPN 2 outputs (-100 to 100 kPa) | With unit selection function | Without lead wire with connector | Single unit (PV, PD individual ports, PV ≠ PD) | Without options | Non-locking push type | ||
MYR 1,490.29 | 1 Piece(s) | 23 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | NPN 2 outputs (-100 to 100 kPa) | With unit selection function | 2‑m lead wire with connector and connector cover | Single unit (PV, PD individual ports, PV ≠ PD) | Without options | Non-locking push type | ||
MYR 1,520.05 | 1 Piece(s) | 17 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | ø2 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | NPN 2 outputs (-100 to 100 kPa) | SI unit fixed | 2‑m lead wire with connector and connector cover | Single unit (PV, PD individual ports, PV ≠ PD) | With bracket for single unit (enclosed with the product for shipment without being assembled) | Non-locking push type | ||
MYR 1,533.19 | 1 Piece(s) | 17 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | NPN 2 outputs (-100 to 100 kPa) | SI unit fixed | 2‑m lead wire with connector and connector cover | Single unit (PV, PD individual ports, PV ≠ PD) | With bracket for single unit (enclosed with the product for shipment without being assembled) / screwdriver operation type (vacuum break flow adjusting needle) | Non-locking push type | ||
MYR 909.65 | 1 Piece(s) | 17 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Fitting Elbow | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | Without vacuum pressure switch | - | - | Single unit (PV, PD individual ports, PV ≠ PD) | With bracket for single unit (enclosed with the product for shipment without being assembled) | Non-locking push type | ||
MYR 922.79 | 1 Piece(s) | 17 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Fitting Elbow | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | Without vacuum pressure switch | - | - | Single unit (PV, PD individual ports, PV ≠ PD) | With bracket for single unit (enclosed with the product for shipment without being assembled) / screwdriver operation type (vacuum break flow adjusting needle) | Non-locking push type | ||
MYR 865.67 | 1 Piece(s) | 17 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | 1/8 (ø3.18) | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | Without vacuum pressure switch | - | - | Single unit (PV, PD individual ports, PV ≠ PD) | Without options | Non-locking push type | ||
MYR 1,611.23 | 1 Piece(s) | 21 Day(s) | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | Output 1 to 5 V, accuracy ±2% F.S. or less (0 to -101 kPa) | - | Without lead wire with connector | Single unit (PV, PD individual ports, PV ≠ PD) | Without options | Non-locking push type | ||
MYR 1,234.60 | 1 Piece(s) | 17 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Fitting Elbow | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | Output 1 to 5 V, accuracy ±2% F.S. or less (0 to -101 kPa) | - | Without lead wire with connector | Single unit (PV, PD individual ports, PV ≠ PD) | Without options | Non-locking push type | ||
MYR 1,208.22 | 1 Piece(s) | 21 Day(s) | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | Without vacuum pressure switch | - | - | Single unit (PV, PD individual ports, PV ≠ PD) | Without options | Locking type (tool required) semi-standard | ||
MYR 1,249.27 | 1 Piece(s) | 21 Day(s) | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | Without vacuum pressure switch | - | - | Single unit (PV, PD individual ports, PV ≠ PD) | With bracket for single unit (enclosed with the product for shipment without being assembled) | Locking type (tool required) semi-standard | ||
MYR 2,037.22 | 1 Piece(s) | 21 Day(s) | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | NPN 2 outputs (0 to -101 kPa) | With unit selection function | 2‑m lead wire with connector and connector cover | Single unit (PV, PD individual ports, PV ≠ PD) | Without options | Locking type (tool required) semi-standard | ||
MYR 1,573.69 | 1 Piece(s) | 23 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | NPN 2 outputs (0 to -101 kPa) | With unit selection function | 2‑m lead wire with connector and connector cover | Single unit (PV, PD individual ports, PV ≠ PD) | With bracket for single unit (enclosed with the product for shipment without being assembled) | Locking type (tool required) semi-standard | ||
MYR 1,556.14 | 1 Piece(s) | 23 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | NPN 2 outputs (0 to -101 kPa) | With unit selection function | 2‑m lead wire with connector and connector cover | Single unit (PV, PD individual ports, PV ≠ PD) | Screwdriver operation type (vacuum break flow adjusting needle) | Locking type (tool required) semi-standard | ||
MYR 1,506.84 | 1 Piece(s) | 17 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | NPN 2 outputs (0 to -101 kPa) | SI unit fixed | Without lead wire with connector | Single unit (PV, PD individual ports, PV ≠ PD) | With bracket for single unit (enclosed with the product for shipment without being assembled) | Locking type (tool required) semi-standard | ||
MYR 1,572.69 | 1 Piece(s) | 17 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | NPN 2 outputs (0 to -101 kPa) | SI unit fixed | 2‑m lead wire with connector and connector cover | Single unit (PV, PD individual ports, PV ≠ PD) | With bracket for single unit (enclosed with the product for shipment without being assembled) | Locking type (tool required) semi-standard | ||
MYR 1,555.15 | 1 Piece(s) | 17 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Fitting Elbow | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | NPN 2 outputs (0 to -101 kPa) | SI unit fixed | 2‑m lead wire with connector and connector cover | Single unit (PV, PD individual ports, PV ≠ PD) | Without options | Locking type (tool required) semi-standard | ||
MYR 2,095.50 | 1 Piece(s) | 21 Day(s) | Filter / Vacuum Destructive Valve | - | - | One-Touch Fitting Elbow | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | NPN 2 outputs (0 to -101 kPa) | SI unit fixed | 2‑m lead wire with connector and connector cover | Single unit (PV, PD individual ports, PV ≠ PD) | With bracket for single unit (enclosed with the product for shipment without being assembled) | Locking type (tool required) semi-standard | ||
MYR 2,037.22 | 1 Piece(s) | 21 Day(s) | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | PNP 2 outputs (0 to -101 kPa) | With unit switching function (default: psi) | 2‑m lead wire with connector and connector cover | Single unit (PV, PD individual ports, PV ≠ PD) | Without options | Locking type (tool required) semi-standard | ||
MYR 2,037.22 | 1 Piece(s) | 21 Day(s) | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | NPN 2 outputs (-100 to 100 kPa) | With unit selection function | 2‑m lead wire with connector and connector cover | Single unit (PV, PD individual ports, PV ≠ PD) | Without options | Locking type (tool required) semi-standard | ||
MYR 2,054.88 | 1 Piece(s) | 21 Day(s) | Filter / Vacuum Destructive Valve | - | - | One-Touch Fitting Elbow | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | NPN 2 outputs (-100 to 100 kPa) | With unit selection function | 2‑m lead wire with connector and connector cover | Single unit (PV, PD individual ports, PV ≠ PD) | Without options | Locking type (tool required) semi-standard | ||
MYR 1,506.84 | 1 Piece(s) | 17 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | NPN 2 outputs (-100 to 100 kPa) | SI unit fixed | Without lead wire with connector | Single unit (PV, PD individual ports, PV ≠ PD) | With bracket for single unit (enclosed with the product for shipment without being assembled) | Locking type (tool required) semi-standard | ||
MYR 1,542.01 | 1 Piece(s) | 23 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | NPN 2 outputs (-100 to 100 kPa) | SI unit fixed | 2‑m lead wire with connector and connector cover | Single unit (PV, PD individual ports, PV ≠ PD) | Without options | Locking type (tool required) semi-standard | ||
MYR 1,680.98 | 1 Piece(s) | 21 Day(s) | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | Output 1 to 5 V, accuracy ±2% F.S. or less (0 to -101 kPa) | - | Without lead wire with connector | Single unit (PV, PD individual ports, PV ≠ PD) | Without options | Locking type (tool required) semi-standard | ||
MYR 1,304.86 | 1 Piece(s) | 17 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | Output 1 to 5 V, accuracy ±2% F.S. or less (0 to -101 kPa) | - | Without lead wire with connector | Single unit (PV, PD individual ports, PV ≠ PD) | With bracket for single unit (enclosed with the product for shipment without being assembled) | Locking type (tool required) semi-standard | ||
MYR 1,689.83 | 1 Piece(s) | 21 Day(s) | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | ø2 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector with lead wire | Output 1 to 5 V, accuracy ±2% F.S. or less (-100 to 100 kPa) | - | Without lead wire with connector | Single unit (PV, PD individual ports, PV ≠ PD) | Without options | Locking type (tool required) semi-standard | ||
MYR 1,471.74 | 1 Piece(s) | 17 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector, without connector | NPN 2 outputs (0 to -101 kPa) | With unit selection function | 2‑m lead wire with connector and connector cover | Single unit (PV, PD individual ports, PV ≠ PD) | Without options | Non-locking push type | ||
MYR 1,502.43 | 1 Piece(s) | 17 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector, without connector | NPN 2 outputs (0 to -101 kPa) | With unit selection function | 2‑m lead wire with connector and connector cover | Single unit (PV, PD individual ports, PV ≠ PD) | With bracket for single unit (enclosed with the product for shipment without being assembled) | Non-locking push type | ||
MYR 1,515.65 | 1 Piece(s) | 17 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector, without connector | NPN 2 outputs (0 to -101 kPa) | With unit selection function | 2‑m lead wire with connector and connector cover | Single unit (PV, PD individual ports, PV ≠ PD) | With bracket for single unit (enclosed with the product for shipment without being assembled) / screwdriver operation type (vacuum break flow adjusting needle) | Non-locking push type | ||
MYR 1,436.57 | 1 Piece(s) | 23 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | 5/32 (Ø3.97) | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector, without connector | PNP 2 outputs (-100 to 100 kPa) | With unit switching function (default: psi) | Without lead wire with connector | Single unit (PV, PD individual ports, PV ≠ PD) | With bracket for single unit (enclosed with the product for shipment without being assembled) | Non-locking push type | ||
MYR 861.34 | 1 Piece(s) | 17 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Fitting Elbow | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector, without connector | Without vacuum pressure switch | - | - | Single unit (PV, PD individual ports, PV ≠ PD) | Without options | Non-locking push type | ||
MYR 874.48 | 1 Piece(s) | 17 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Fitting Elbow | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector, without connector | Without vacuum pressure switch | - | - | Single unit (PV, PD individual ports, PV ≠ PD) | Screwdriver operation type (vacuum break flow adjusting needle) | Non-locking push type | ||
MYR 848.12 | 1 Piece(s) | 17 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | 1/8 (ø3.18) | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector, without connector | Without vacuum pressure switch | - | - | Single unit (PV, PD individual ports, PV ≠ PD) | Without options | Non-locking push type | ||
MYR 1,234.22 | 1 Piece(s) | 23 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector, without connector | Output 1 to 5 V, accuracy ±2% F.S. or less (0 to -101 kPa) | - | Without lead wire with connector | Single unit (PV, PD individual ports, PV ≠ PD) | With bracket for single unit (enclosed with the product for shipment without being assembled) | Non-locking push type | ||
MYR 1,216.59 | 1 Piece(s) | 23 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Fitting Elbow | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector, without connector | Output 1 to 5 V, accuracy ±2% F.S. or less (0 to -101 kPa) | - | Without lead wire with connector | Single unit (PV, PD individual ports, PV ≠ PD) | Without options | Non-locking push type | ||
MYR 1,234.60 | 1 Piece(s) | 17 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector, without connector | Output 1 to 5 V, accuracy ±2% F.S. or less (-100 to 100 kPa) | - | Without lead wire with connector | Single unit (PV, PD individual ports, PV ≠ PD) | With bracket for single unit (enclosed with the product for shipment without being assembled) | Non-locking push type | ||
MYR 900.84 | 1 Piece(s) | 17 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Coupling | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector, without connector | Without vacuum pressure switch | - | - | Single unit (PV, PD individual ports, PV ≠ PD) | Without options | Locking type (tool required) semi-standard | ||
MYR 1,537.60 | 1 Piece(s) | 23 Day(s) or more | Filter / Vacuum Destructive Valve | - | - | One-Touch Fitting Elbow | Ø4 | M5 | Single Item | - | - | - | For vacuum pump system (without silencer) | Normally closed / normally closed | 24 V DC | L-type plug connector, without connector | NPN 2 outputs (-100 to 100 kPa) | SI unit fixed | 2‑m lead wire with connector and connector cover | Single unit (PV, PD individual ports, PV ≠ PD) | Without options | Locking type (tool required) semi-standard |
Loading...
| Type | Unit | Operating Temp. Range(°C) | -5::50 |
|---|
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy