(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
[Features]
Omron product. A blackout detector that monitors the power supply (commercial AC power) of the control unit. Instantaneous detection of voltage drops, power failures, and instantaneous power failures. Input voltage is AC100V or AC200V by individual specification.
Japanese Only
Part Number
Configured Part Number is shown.
S87A-11N

Power Failure Detector appearance

Power Failure Detector outline diagram

Power Failure Detector dimensional outline drawing; unit: mm
Note. Terminal screws: size M3.5 × 8 SEMs screws

Power Failure Detector dimensional outline drawing; unit: mm

Power Failure Detector mounting hole drilling outline drawing; unit: mm
Note. When installing two or more units, make sure to install with a minimum distance of L=22.5 mm between each unit.

Power Failure Detector internal connection diagram

Power Failure Detector external connection diagram

Power Failure Detector names of parts and terminal layout
| Item | Model | ||
|---|---|---|---|
| Model S87A-11N | Model S87A-12N | ||
| Rated Voltage | 100/110/120 V AC | 200/220/240 V AC | |
| Allowable Voltage Fluctuation Range | 85 to 132 V | 170 to 264 V | |
| Rated Power Consumption | 1.5 VA or less | 2.0 VA or less | |
| Rated Frequency | 50/60 Hz | ||
| Detection Time* | 10 ms±1.5 ms / 20 ms±1.5 ms (switching method) | ||
| Voltage Detection | 70 to 80 V | 140 to 160 V | |
| Open collector output of transistor: 30 V DC, 150 mA Max. | |||
| Output | Leakage Current | 0.1 mA (When 30 V DC is applied) | |
| Residual Voltage | 2 V (At 150 mA) | ||
| Ambient Operating Temperature | -10 to +60°C (However, there should be no condensation or freezing.) | ||
| Ambient Operating Humidity | 35 to 85% | ||
| Insulation Resistance | At 500 V megger, 100 MΩ Min. (between input and output circuits) | ||
| Dielectric Withstand Voltage | 2,000 V AC for 1 min (between input and output circuits) | ||
| Vibration Resistance | Must produce no abnormalities at 10 to 55 Hz, with single amplitude of 0.375mm for 2h in 3 directions | ||
| Shock Resistance | Must produce no abnormalities at 294 m/s2, 3 times each in 6 directions | ||
*The measurement conditions for detection time are from when the power is cut at the 90° phase on the electric waveform until the output signal phase is inverted.
| Part Number |
|---|
| S87A-11N |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship |
|---|---|---|---|---|
MYR 517.44 | 1 Piece(s) | 1 Day(s) |
Loading...
| Rated Input Voltage(V) | AC100/110/120V | Detection Voltage(V) | AC70 to 80V |
|---|
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy