DC Clamp Logger ZN-DCC11

DC Clamp Logger  ZN-DCC11

Simple measurement of direct current values. Clamp-type logger

[Features]
· Start logging with the touch of a button. Data is logged into the internal memory at predetermined intervals (the default value is 1 second).
· The average, maximum and minimum values from the logged data can be checked on the device.
· High-speed sampling. Minimum sampling time is 500ms.
· Long-lasting battery. Six days of recording is possible on one full charge. *At 1 second intervals (23°C).
· The battery will last approximately 27 days at a recording interval of 1 minute.
· Environment resistant.
· Operating temperature range: -10°C to +55°C.
· Operates even in extreme temperature environments.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

ZN-DCC11

DC Clamp Logger ZN-DCC11 Specifications

DC Clamp Logger ZN-DCC11: related images

ZN-DCC11 appearance
Power supply: secondary lithium battery (USB charging)

DC Clamp Logger ZN-DCC11: related images

ZN-DCC11 dimensional drawing
Unit: mm

ZN-DCC11 Ratings

FormatModel ZN-DCC11
Rated Measurement Current±200 A DC
Maximum Number Of Times Clamped10,000 Times
Inner Diameter Of Clampφ23
Applicable Circuit Voltage500 V DC max.
Display7-segment LCD with 4 digits on 1 row, supplemental information indicators and CHARGE LED
Recording Interval0.5 s, 1 s, 2 s, 5 s, 10 s, 20 s, 30 s or 1 min (can be set with utility software)
Conversion Function *1Instantaneous Power
Internal Memory Capacity105 Files Max. *2
Approx. 1,700,000 data items (1 data item: approx. 4 bytes) *3
Power SupplySecondary Lithium Battery (charged via USB port on a PC)
Current Consumption75 mA Max. (maximum current consumption when connected via USB)
Battery Life *4Approx. 6 days (with recording interval at 1 s and ambient temperature of 23°C)
Charging TimeApprox. 3 Hours (estimated time with an ambient temperature of 23°C, starting from a battery level of 0)
Operating Temperature RangeBattery powered: -10°C to +55°C (no condensation or freezing)
Charging via USB: 0°C to 40°C (no condensation or freezing)
Operating Humidity Range20 to 80% RH (no condensation or freezing)
Storage Temperature And Humidity Range-10°C to +60°C, 20 to 80% RH (no condensation or freezing)
Insulation ResistanceWith USB Connector Case: 50 MΩ Min. (500 V DC Mega)
Dielectric Withstand VoltageWith USB Connector Case: 1,000 V AC, 50/60 Hz for 1 min
Vibration (Resistance)10 to 150 Hz, with double amplitude of 0.7 mm, acceleration of 50 m/s2 for 80 min each in X, Y and Z directions
Shock (Resistance)150 m/s2 3 times each in 6 directions (up/down, left/right and forward/backward) *5
MaterialABS
USB Insertion/Removal Durability5,000 Times
Degree Of ProtectionIP30
Weight (Packaged)Approx. 300 g
AccessoriesInstruction manual, utility disc (CD-ROM) *6, USB cable (mini-B), and hand strap (comes attached to the logger)

*1. Instantaneous power is calculated using the measured current and set voltage. Make sure to set the correct number.
*2. A single file is created for each time logging is started/stopped. If the maximum number of files is exceeded, an E12 error will be displayed and logging will be unable to start.
*3. If the number of data items reaches the internal memory capacity, an E11 error will be displayed and logging will stop.
*4. The duration of the battery life depends on the measurement environment, recording interval and operating mode.
*5. Install the product in a location where it will not be subject to impact.
*6. The utility disc contains the utility software, USB driver, PDF manual file, etc.
   System requirements for the enclosed software: OS: Windows XP SP3 / Windows 7 (64‑bit supported only for Windows 7)
CPU: Intel-equivalent processor of 1.5 GHz minimum, Memory: 1 GB minimum (2 GB or higher is recommended)

ZN-DCC11 Measurement Specifications

FormatModel ZN-DCC11
Rated Measurement Current±200 A DC
Allowable Measurement Current110% of rated measurement current
Current Accuracy*0 to ±24.9 A±2.0% rdg ±5 digits
±25.0 to ±99.9 A±2.5% rdg ±5 digits
±100 to ±200 A±2.0% rdg ±1 digits
Logged ValuesCurrent Values
Applicable CircuitDirect Current (DC) Circuit

*At an ambient temperature of 23±10°C and rated input.

Please refer to the catalog for any product information not listed above.

Part Number
ZN-DCC11
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to Ship

MYR 2,173.30

1 Piece(s) 1 Day(s)

Loading...

  1. 1
 

Basic Information

Type Clamp power logger Usage Form Handy External storage Not Applicable
Battery drive time(h) 144 Display Liquid crystal 7 segment 4 digits 1 levels Measurement DC Current Range (A) ±200
Measurement Application Circuit (Power Logger) DC System Circuit (DC) Function Instantaneous Power Clamp Inner Diameter (mm) φ23
Material ABS Protective Structure IP30

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7960 8499 / FAX:(60) 3 7960 7499
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)