Solid State/Timer H3Y

Solid State/Timer H3Y

[Features]
· Ultra-small timer for use in sequence control incorporating a dedicated IC.
· High precision with a repeat error of ±1% (including first time value).
· Recover time including recovery during operation is less than 100ms.
· Easy time setting using the large dial in common with the +- driver.
· Semi-multi power source voltages.
· A standard product which acquired UL, CSA standards.
· EN61812-1 Compatible, corresponds to the CE mark.

PDF

Japanese Only

Product Features

H3Y Solid-State Timer: related image

H3Y external appearance

Maximum Scale TimeSet Time Range
0.5 s0.04 s to 0.5 s
1 s0.1 s to 1.0 s
5 s0.2 s to 5.0 s
10 s0.5 s to 10 s
30 s1.0 s to 30 s
60 s2.0 s to 60 s
120 s5.0 s to 120 s
3 min0.1 min to 3 min
5 min0.2 min to 5 min
10 min0.5 min to 10 min
30 min1.0 min to 30 min
60 min2.0 min to 60 min
3 h0.1 h to 3 h

Rating

FormatSeries H3Y-2 (-0)Series H3Y-4 (-0)
Power Supply Voltage*6· 100 to 120 V AC (50/60 Hz) · 200 to 230 V AC (50/60 Hz)
· 24 V AC (50/60 Hz)*1
· 12 V DC, 24 V DC, 48 V DC, 100 to 110 V DC, 125 V DC*2, *3
Allowable Voltage Variation Range85 to 110% of power supply voltage (however, 90 to 110% of power supply voltage for 12 V DC specifications only)*4
Power Consumption100 to 120 V AC1.5 VA (At 120 V AC)
200 to 230 V AC1.8 VA (At 230 V AC)
24 V AC1.5 VA (At 24 V AC)
12 V DC0.9 W (At 12 V DC)
24 V DC0.9 W (At 24 V DC)
48 V DC1.0 W (At 48 V DC)
100 to 110 V DC1.3 W (At 110 V DC)
125 V DC1.3 W (At 125 V DC)
Recovery Voltage10% or more of power supply voltage*5
Control Output250 V AC, 5 A, resistive load (cosφ = 1)
Minimum applied load 5 V DC, 1 mA (P level, reference value)
Contact material: Ag
250 V AC, 3 A, resistive load (cosφ = 1)
Minimum applied load 1 V DC, 1 mA (P level, reference value)
Contact material: Au clad + Ag alloy
Ambient Operating Temperature-10 to +50°C (No Freezing)
Storage Temperature-25 to +65°C (No Freezing)
Ambient Operating Humidity35 to 85%

*1. Do not use the inverter output as a power supply.
*2. Usable up to single-phase full-wave rectification power supply.
*3. 12 V DC is for the H3Y-2 and H3Y-2-0 series only.
*4. When continuously using at an ambient operating temperature of 50°C, use at 90 to 110% of the power supply voltage (95 to 110% for 12 V DC).
*5. For reliable recovery, set to 10 V AC for 100 to 120 V AC, 20 V AC for 200 to 230 V AC, and 10 V DC or less for 100 to 110 V DC.
*6. With DC power-supply-voltage type only, the product is equipped with a counter electromotive force prevention diode.

Performance

FormatSeries H3Y-2 (-0)Series H3Y-4 (-0)
Variations In Operating Time±1% or less (at maximum scale time)*1
Set Error±10% ±50 ms or less (at maximum scale time)
Recovery Time0.1 s or less (including recovery during operation)
Voltage Effect±2% or less (at maximum scale time)*1
Temperature Effect±2% or less (at maximum scale time)*1
Insulation Resistance100 MΩ or more (measurement at 500 V DC megger)
Withstand Voltage2,000 V AC, 50/60 Hz, 1 min (between conductive part terminal and exposed non-charging metal part, excluding the terminal screw part)
2,000 V AC, 50/60 Hz, 1 min (between control output and operation circuit)
2,000 V AC, 50/60 Hz, 1 min (2-pole type between different pole contacts)
1,500 V AC, 50/60 Hz, 1 min (4-pole type between different pole contacts)
1,000 V AC, 50/60 Hz, 1 min (between discontinuous contacts)
Impulse Voltage3 kV between power supply terminals; however, 1 kV for 12 V DC, 24 V DC and 48 V DC,
4.5 kV between the conductive part terminal and exposed non-charging metal part; however, 1.5 kV for 12 V DC, 24 V DC and 48 V DC
Noise ResistanceSquare-wave noise by noise simulator (pulse width 100 ns/1 μs rise 1 ns) ±1.5 kV
Electrostatic Strength4 kV (Malfunction), 8kV (Destruction)
VibrationEndurance10 to 55 Hz, half amplitude 0.75 mm, 3 directions, 1 h each
Malfunction10 to 55 Hz, half amplitude 0.5 mm, 3 directions, 10 min each
ShockEndurance1,000 m/s2, 6 directions, 3 times each*2
Malfunction100m/s2, 6 directions, 3 times each
LifeMechanical10 million operations or more (no load, switching frequency 1,800 operations/h)
Electrical2-pole, 500,000 operations or more (250 V AC, 5 A, resistive load, switching frequency 1,800 operations/h) (room temperature)
4-pole, 200,000 operations or more (250 V AC, 3 A, resistive load, switching frequency 1,800 operations/h) (room temperature)
Protective StructureIP40
MassApprox. 50 g

*1. For 0.5 s specifications, ±10 ms is added to the above characteristics.
*2. Condition when carrying out impact resistance testing with the timer alone.

  • *Refer to the catalog for types and models other than those listed above.
Part Number
H3Y-2 AC100-120 60M
H3Y-2 AC200-230 60M
H3Y-2 DC24 60M
H3Y-4 DC24 60M
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipTime specifications
(s)
Power Supply Voltage Rated power supply voltage
(V)
Contact Configuration

MYR 190.72

1 Piece(s) 1 Day(s) 2.0m to 60mAC-dedicatedAC100 to 120Time Limit 2c

MYR 190.72

1 Piece(s) 1 Day(s) 2.0m to 60mAC-dedicatedAC200 to 230Time Limit 2c

MYR 163.61

1 Piece(s) 1 Day(s) 2.0m to 60mDedicated to DCDC24Time Limit 2c

MYR 175.20

1 Piece(s) 1 Day(s) 2.0m to 60mDedicated to DCDC24Time Limit 4c

Loading...

  1. 1
 

Basic Information

Type Timer Display method Analog Output Method Relay
Representative Standard CE / UL / CCC / CSA Dimension vertical(mm) 52.6 Dimension width(mm) 28
Dimension depth(mm) 21.5 Time ranges = N 1 range Terminal shape Plug-in terminal