[Features]
· Large-capacity rocker switch with reset function.
· Reset feature triggered by an external signal; an effective energy saver.
· An exclusive switching mechanism provides superior resistance to inrush currents and switching at 20A.
· Contact configuration: Double pole, double throw.
· Contact gap 3 mm or larger.
· UL/cUL certified.
· EN standard compliant.
Japanese Only
Part Number
Configured Part Number is shown.
A8G-107-1-24

A8G series appearance

Unit: mm
Operating properties
Force required for operation OF Max: 19.6 N
| Item | Non-inductive Load (A) | Inductive Load (A) | ||
|---|---|---|---|---|
| Rated Voltage (V) | Resistive Load | Lamp Load | Inductive Load | Electric Motor Load |
| 250 V AC | 20 | 10 | 8 | 8 |
Note 1. Lamp load has a 10x inrush current.
Note 2. Inductive loads will have a power factor of 0.4 or higher (AC).
Note 3. Electric motors have a 6x inrush current.
Note 4. The rated values described above were tested in the conditions below.
| Rated Voltage (V) (Usable Voltage Range) | Open Contact Voltage (Coil Temperature 20 ±2°C) | Rated Value Excitation Current (Coil Temperature 20 ±2°C) | Coil Resistance (Coil Temperature 20 ±2°C) | Permitted Application Time |
|---|---|---|---|---|
| 24 V DC ±10% (21.6 to 26.4 V DC) | 21.6 V or less | 185 mA ±20% | 130Ω ±20% | 100 ms or more 1s or less |
Note 1. Please do not flow current to the coil for over 10 seconds. This may cause loss of performance.
Note 2. If the reset coil is controlled using a semiconductor element, etc., make sure that any residual voltage generated due to leakage current is 2.4 V DC or less.
| Permitted Operation Frequency | Mechanical | Switch operation: 7 times/min. or less; Coil operation: 7 times/min. or less |
|---|---|---|
| Electrical | 20 times/min. or less | |
| Insulation Resistance | 100 MΩ or higher (insulation resistance meter at 500 V DC) | |
| Contact Resistance (Initial Value) | 100 mΩ or lower (6 to 8 V DC, 1 A voltage drop method) | |
| Withstand Voltage | Between Same Pole Terminals | 2,000 V AC 50/60 Hz 1 min |
| Between Different Pole Terminals | 2,000 V AC 50/60 Hz 1 min | |
| Metal And Ground Components For Charging | 4,000 V AC 50/60 Hz 1 Min. | |
| Vibration | Malfunction | 10 to 55 Hz double amplitude 1.5 mm (malfunction within 1 ms) |
| Shock | Malfunction | 98 m/s2 or higher (malfunction within 1 ms) |
| Durability | Max. 500 m/s2 | |
| Durability | Electrical | Switch operation: 50,000 times or more; Coil operation: 10,000 times or more |
| Mechanical | Switch operation: 100,000 times or more | |
| Inrush Current | Max. 100 A | |
| Protective Structure | IEC IP40 | |
| Open Contact Time * | 100 ms or less | |
| Operating Temperature Range | -10 to +55℃ (with no icing and no condensation) | |
| Operating Humidity Range | 45 to 85% | |
*Time between applying voltage to the coil and when the contact (between 1-2, 4-5) opens.
| Part Number |
|---|
| A8G-107-1-24 |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship |
|---|---|---|---|---|
MYR 66.23 | 1 Piece(s) | 1 Day(s) |
Loading...
| Shape | Rectangle | Illumination | Non-Illumination | Contact Configuration | 2-pole double throw |
|---|---|---|---|---|---|
| With key | NA | Terminal shape | Tab Terminal | Protection function (environmentally resistant) | Available |
| Dimension vertical(mm) | 37 | Dimension width(mm) | 27 | Dimension depth(mm) | 33 |
| Contact rated 1 (resistant load)(V)/(A) | AC250/20 | Works with micro loads | NA | Reset function (external control) | Available |
| Operation Unit | Integrated style | Operating unit marking | NA | Button color | Black |
| Case color | Black | Protective Structure | IP40 |
Please check the type/dimensions/specifications of the part A8G-107-1-24 in the Locker Switch With Reset Function A8G series.




![Lock Switch [R19B]](http://stg0-my.misumi-ec.com/linked/material/el/TAW1/PHOTO/TAW1_58.jpg?$product_recommend_b$)
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy