(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
[Features]
· A surface mountable dual-pole relay for signal switching with which the terminal protrudes from the side.
· Features a long terminal shape. The soldered parts have a high level of connection reliability over long periods (surface mounted terminal type).
· An internal L-type terminal that allows for high-density mounting (surface mounted terminal type).
· Its unique terminal structure makes it easier to increase the temperature of the terminal during IRS mounting, providing good soldering properties (surface mounted terminal type).
· Features a high withstand voltage between coil-contacts of 2,000VAC. Also features an impulse withstand voltage of 2,500V2 × 10 μs (Telcordia standard).
· Achieves a high-sensitivity rated power consumption of 140mW.
· A small sized type with a height of 9.4 mm, a width of 7.5 mm and a length of 15 mm.
· The use of heat-resistant materials supports IRS mounting methods.
· The standard type is UL and CSA standard certified.
· The series now includes terminal types for printed circuit boards (G65-2).
· EN60950certified types are also available (-Y type).
Japanese Only
Part Number
Configured Part Number is shown.

G6S-2/G6S-2-Y external appearance

G6S-2/G6S-2-Y dimensional outline drawing
Units: mm
The general dimensional tolerance is ±0.3 mm.

PCB processing dimensions
Units: mm
The general dimensional tolerance is 0.3 mm.

G6SK-2 external appearance

G6SK-2 dimensional outline drawing
Units: mm
The general dimensional tolerance is ±0.3 mm.

PCB processing dimensions
Units: mm
The general dimensional tolerance is 0.3 mm.

G6SU-2 external appearance

G6SU-2 dimensional outline drawing
Units: mm
The general dimensional tolerance is ±0.3 mm.

PCB processing dimensions
Units: mm
The general dimensional tolerance is ±0.3 mm.
| Classification | Items | Rated Current (mA) | Coil Resistance (Ω) | Operating Voltage (V) | Release Voltage (V) | Maximum Allowable Voltage (V) | Power Consumption (mW) | |
|---|---|---|---|---|---|---|---|---|
| Rated Voltage (V) | ||||||||
| Model G6S-2 | DC | 4.5 | 31 | 145 | 75% or Less | 10% or More | 200% (23°C) | Approx. 140 |
| 5 | 28.1 | 178 | ||||||
| 12 | 11.7 | 1,028 | ||||||
| 24 | 8.3 | 2,880 | 170% (23°C) | Approx. 200 | ||||
| Model G6S-2-Y | DC | 12 | 16.7 | 720 | 75% or Less | 10% or More | 170% (23°C) | Approx. 200 |
| 24 | 9.6 | 2,504 | Approx. 230 | |||||
| Classification | Items | Rated Current (mA) | Coil Resistance (Ω) | Set Voltage (V) | Reset Voltage (V) | Maximum Allowable Voltage (V) | Power Consumption (mW) | |
|---|---|---|---|---|---|---|---|---|
| Rated Voltage (V) | ||||||||
| Model G6SK-2 | DC | 5 | 40 | 125 | 75% or Less | 75% or Less | 170% (23°C) | Approx. 200 |
| 12 | 16.7 | 720 | ||||||
| Classification | Items | Rated Current (mA) | Coil Resistance (Ω) | Set Voltage (V) | Reset Voltage (V) | Maximum Allowable Voltage (V) | Power Consumption (mW) | |
|---|---|---|---|---|---|---|---|---|
| Rated Voltage (V) | ||||||||
| Model G6SU-2 | DC | 3 | 33.3 | 90 | 75% or Less | 75% or Less | 180% (23°C) | Approx. 100 |
| Load | Resistance Load |
|---|---|
| Rated Load | 125 V AC 0.5 A, 30 V DC 2 A |
| Rated Conduction Current | 2 A |
| Maximum Contact Voltage Value | 250 V AC, 220 V DC |
| Maximum Contact Current Value | 2 A |
| Type | Single Stable Type Model G6S-2 | Single Coil Latching Type Model G6SU-2 | Dual Coil Latching Type Model G6SK-2 | Single Stable Type Model G6S-2-Y | |
|---|---|---|---|---|---|
| Contact Resistance *1 | 75 mΩ or Less | ||||
| Operation (Set) Time *2 | 4 ms or Less (Approx. 2.5 ms) | 4 ms or Less (Approx. 2 ms) | 4 ms or Less (Approx. 2.5 ms) | ||
| Recovery (Reset) Time *2 | 4 ms or Less (Approx. 1.5 ms) | 4 ms or Less (Approx. 2 ms) | 4 ms or Less (Approx. 1.5 ms) | ||
| Minimum Set/Reset Pulse Width | - | 10 ms | - | ||
| Insulation Resistance *3 | 1,000 MΩ or More (with 500 V DC Megohmmeter) | ||||
| Withstand Voltage | Between Coil and Contact | 2,000 V AC 50/60 Hz 1 min | 1,000 V AC 50/60 Hz 1 min | 2,000 V AC 50/60 Hz 1 min | |
| Between Contacts of Different Polarities | 1,500 V AC 50/60 Hz 1 min | ||||
| Between Contacts of Same Polarity | 1,000 V AC 50/60 Hz 1 min | ||||
| Between Set/Reset Coils | - | 500 V AC 50/60 Hz 1 min | - | ||
| Insulation Distance | Between Coil and Contact | Space: 1 mm, Creepage: 1.5 mm | Space: 2 mm, Creepage: 2 mm | ||
| Impulse Withstand Voltage | Between Coil and Contact | 2,500 V 2 ×10 μs, 1,500 V 10 × 160 μs | 1,500 V 10 × 160 μs | 2,500 V 2 ×10 μs, 1,500 V 10 × 160 μs | |
| Between Contacts of Different Polarities | 2,500 V 2 × 10 μs, 1,500 V 10 × 160 μs | ||||
| Between Contacts of Same Polarity | 1,500 V 10 × 160 μs | ||||
| Vibration | Durability | 10 to 55 to 10 Hz, Semi Amplitude 2.5 mm (Double Amplitude 5 mm) | |||
| Malfunction | 10 to 55 to 10 Hz, Semi Amplitude 1.65 mm (Double Amplitude 3.3 mm) | ||||
| Shock / Impact | Durability | 1,000 m/s2 | |||
| Malfunction | 750 m/s2 | ||||
| Durability | Mechanical | 100,000,000 Times or More (Switching Frequency: 36,000 Times/h) | |||
| Electrical | AC 100,000 Times or More (Rated Load, Switching Frequency: 1,800 Times/h) DC 100,000 Times or More (Rated Load, Switching Frequency: 1,200 Times/h) | ||||
| Failure Rate P Level (Reference Value *4) | DC 10 mV 10 μA | ||||
| Ambient Operating Temperature | -40 to +85°C (Assuming No Freezing or Condensation), Dual Coil Latching Type 24 V DC Specification and Y Type 24 V DC Specification Only -40 to +70°C (Assuming No Freezing or Condensation) | ||||
| Operating Ambient Humidity | 5 to 85%RH | ||||
| Weight | Approx. 2 g | ||||
*1. Measurement conditions: 1 V DC, 10 mA, voltage drop method.
*2. The values within ( ) are the actual values.
*3. Measurement conditions: Measuring the same spot for the withstand voltage items using a 500 V DC insulation resistance meter. (Except between set and reset coils)
*4 This value is obtained with a switching frequency of 120 times/min. and a contact resistance failure value of 50 Ω. These values may vary depending on switching frequency and operating conditions, meaning it is always recommended to double-check under actual load conditions.
| Part Number |
|---|
| G6S-2 DC4.5 |
| G6S-2 DC5 |
| G6S-2 DC12 |
| G6S-2 DC24 |
| G6S-2-Y DC12 |
| G6S-2-Y DC24 |
| G6SU-2 DC3 |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Latch function | Coil rated voltage (DC) (V) | Safety standards | Classification |
|---|---|---|---|---|---|---|---|---|
MYR 23.34 | 1 Piece(s) | 1 Day(s) | NA | 4.5 | - | Single stable shape | ||
MYR 23.34 | 1 Piece(s) | 1 Day(s) | NA | 5 | - | Single stable shape | ||
MYR 23.34 | 1 Piece(s) | 1 Day(s) | NA | 12 | UL / CSA | Single stable shape | ||
MYR 25.70 | 1 Piece(s) | 1 Day(s) | NA | 24 | UL / CSA | Single stable shape | ||
MYR 24.55 | 1 Piece(s) | 1 Day(s) | NA | 12 | - | Single stable shape | ||
MYR 27.63 | 1 Piece(s) | 1 Day(s) | NA | 24 | - | Single stable shape | ||
MYR 24.12 | 1 Piece(s) | 2 Day(s) or more | Available | 3 | - | 1-winding latching type |
Loading...
| Application | For Signals | Contact Configuration | 2c | Terminal shape | For Circuit Boards |
|---|---|---|---|---|---|
| Contact rated current (minimum value for AC and DC)(A) | 0.5 | Dimension height(mm) | 9.2 | Dimension width(mm) | 14.8 |
| Dimension depth(mm) | 7.3 | Protective Structure | Plastic seal type | Contact mechanism | Crossbar twin |
| Circuit Board Mounting | Circuit Board Hole Insertion | AC rated load(V)/(A) | AC125/0.5 | DC rated load(V)/(A) | DC30/2 |








How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy