[Features]
· EN standard awarded small and slim safety relay.
· Relay with force-guided contacts (EN50205/ClassAVDE certification).
· Backs up machinery CE marking (machinery directive).
· Use of interlock circuits avoids dangerous conditions for the machinery.
· 4-pole, 6-pole available.
· Terminal wiring makes PWB patterning easy.
· Strengthened insulation between input and output.
· Strengthened insulation in part of electrode gap.
Japanese Only
Part Number
Configured Part Number is shown.

G7SA external appearance
Additional Push-In Plus terminal sockets are used to save wiring work in comparison with traditional screw terminals (wiring time is reduced by 60%* in comparison with traditional screw terminals).
Relay with forcibly guided contacts (EN 50205 / Class A VDE certification)
| Contact Resistance *1 | 100 mΩ max. | |
|---|---|---|
| Operating Time *2 | 20 ms max. | |
| Response Time *3 | 10 ms max. | |
| Recovery Time *2 | 20 ms max. | |
| Operating Voltage | 75% max. relative to rated voltage | |
| Release Voltage | 10% min. relative to rated voltage | |
| Maximum Switching Frequency | Mechanical | 36,000 operations/hr |
| Rated Load | 1,800 operations/hr | |
| Insulation Resistance *4 | 1,000 MΩ min. | |
| Dielectric Strength *5 *6 | Between Coil and Contacts | 4,000 V AC 50/60 Hz for 1 min |
| Between Contacts of Different Polarity | 4,000 V AC 50/60 Hz for 1 min (except for the following) 4 poles: between poles 3 and 4 6 poles: between poles 3 and 5, 4 and 6, and 5 and 6 2,500 V AC 50/60 Hz for 1 min | |
| Between Contacts of Same Polarity | 1,500 V AC 50/60 Hz for 1 min | |
| Vibration | 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) | |
| Shock | Durability | 1,000 m/s2 |
| Malfunction | 100 m/s2 | |
| Durability *7 | Mechanical | 10,000,000 operations min. (switching frequency 36,000 count/hr) |
| Electrical | 100,000 operations min. (Rated load, switching frequency 1,800 operations/hr) | |
| Inductive Load Switching Performance *8 (IEC60947-5-1) | AC15 240 V AC 2 A DC13 24 V DC 1 A | |
| Failure Rate (P Level) (Reference Value *9) | 5 V DC 1 mA | |
| Ambient Operating Temperature *10 | 12 to 48 V DC Specification: -40 to +85°C (assuming no icing or condensation) 110 V DC Specification: -40 to +60°C (assuming no icing or condensation) | |
| Ambient Operating Humidity | 5 to 85% RH | |
| Weight | 4 poles: approx. 22 g 6 poles: approx. 25 g | |
Note 1: The values given above are initial values.
Note 2. Performance characteristic data is measured at a coil temperature of 23°C.
*1. Measurement conditions: 5 V DC, 1 A, voltage drop method.
*2. Measurement conditions: rated voltage operation
Ambient temperature conditions: 23°C
Bounce time not included.
*3. The response time is the time it takes for the a-contacts to open (OFF) after the coil voltage is turned OFF. Contact bounce time is included.
Measurement conditions: rated voltage operation
Ambient temperature conditions: 23°C
*4. Measured with a 500 V DC ohmmeter at the same places that the dielectric strength was checked.
*5. Pole 3 refers to terminals 31-32 or 33-34, pole 4 refers to terminals 43-44, pole 5 refers to terminals 53-54, and pole 6 refers to terminals 63-64.
*6. When using a P7SA socket, the dielectric strength between coil contacts/different poles is 2,500 V AC, 50/60 Hz for 1 min. When using Push-In Plus terminal sockets (P7SA-□FND-PU), the dielectric strength between coil contacts as well as between different poles is 4,000 VAC, 50/60 Hz for 1 min.
*7. The durability is for an ambient temperature of 15 to 35°C and an ambient humidity of 25% to 75%. For the durability performance to the load, refer to the durability curve data.
*8. Inductive load - AC15: cosø = 0.3, DC13: L/R = 48 ms.
*9. This value is based on a switching frequency of 300 operations/min.
*10. 12 to 48 V DC: When operating between 70 and 85°C, reduce the rated carry current of 6 A by 0.1 A for each degree above 70°C. 110 V DC: When operating between 40 and 60°C, reduce the rated carry current of 6 A by 0.27 A for each degree above 40°C.

Model G7SA-3A1B, Model G7SA-2A2B dimensional drawing

Model G7SA-3A1B, Model G7SA-2A2B terminal layout / internal schematics

PCB processing drawing
See the catalog for dimensional drawings for model numbers other than those detailed above.
| Part Number |
|---|
| G7SA-3A3B DC24 |
| G7SA-4A2B DC24 |
| G7SA-5A1B DC24 |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Contact Configuration |
|---|---|---|---|---|---|
MYR 93.00 | 1 Piece(s) | 1 Day(s) | [Other] 3a3b | ||
MYR 93.00 | 1 Piece(s) | 1 Day(s) | [Other] 4a2b | ||
MYR 93.00 | 1 Piece(s) | 1 Day(s) | [Other] 5a1b |
Loading...
| Application | Safety relay | Latch function | NA | Terminal shape | For Circuit Boards |
|---|---|---|---|---|---|
| Contact rated current (minimum value for AC and DC)(A) | 6 | Coil rated voltage (DC)(V) | 24 | Dimension height(mm) | 24 |
| Dimension width(mm) | 50 | Dimension depth(mm) | 13 | Protective Structure | Flux resistant shape |

OMRON
Standard Price : MYR 6.86-
Days to Ship : 1 Day(s) or more



OMRON
Standard Price : MYR 23.61-
Days to Ship : 1 Day(s) or more



How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy