Solid State / Relay G3B / G3BD

Solid State / Relay G3B / G3BD

[Features]
· Plug-in type with the same shape as the MK power relay.
· Overseas standard compliant (-VD type) added to series.
· UL, CSA, EN (VDE certification) standards acquired (-VD type).
· Plug-in type of identical size to model MK (2 varieties).
· Input viewable due to operation display lamp.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

G3B-205S DC4-30

Solid State Relay External Appearance

Solid State Relay G3B/G3BD: related images

G3B/G3BD external appearance

Solid State Relay G3B/G3BD: related images

G3B/G3BD external appearance

Solid State Relay G3B/G3BD: related images

G3B/G3BD dimensional outline drawing

Solid State Relay G3B/G3BD: related images

 

Terminal layout / internal connections (bottom view)

  • The values in parenthesis are for the Model G3BD and Model G3BD-VD. The load can be connected either to the + side or - side.

 

"m-h3--wysiwyg">Ratings (ambient temperature 25°C)

Input

FormatRated VoltageOperating VoltageImpedanceVoltage Level
Operating VoltageRelease Voltage
Model G3B-205S5 to 24 V DC4 to 30 V DC1.5 kΩ +20%, -10%4 V DC max.1 V DC min.
Model G3BD-103S1.5 kΩ +20%, -10%
  • *No indicator.
  • * The given input impedance is for the maximum operating voltage.

* With constant current input circuit system.

Output

FormatApplied Load
Rated Load VoltageLoad Voltage RangeLoad Current *Inrush Current
Model G3B-205S100 to 240 V AC75 to 264 V AC0.1 to 5 A (at 40°C)80 A (60 Hz, 1 cycle)
Model G3BD-103S5 to 110 V DC3 to 125 V DC0.1 to 3 A (at 40°C)12 A (10 ms)

*Differs depending on ambient temperature. For details, see the catalog characteristics data "● Rated Load Current—Ambient Temperature."

Performance

FormatModel G3B-205SModel G3BD-103S
Operating Time1/2 of load power source cycle + 1 ms max.0.5 ms max.
Release Time1/2 of load power source cycle + 1 ms max.2.5 ms max.
Output On Voltage Drop1.6 V (RMS) max.1.5 V max.
Leakage Current5 mA max. (at 100 V AC)
10 mA max. (at 200 V AC)
5 mA max. (125 V DC)
Insulation Resistance100 MΩ min. (with 500 V ohmmeter)
Dielectric Strength1,500 V AC 50/60 Hz for 1 min1,500 V AC 50/60 Hz for 1 min
Vibration10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock1,000 m/s2
Storage Temperature-30 to +100°C (assuming no icing or condensation)
Ambient Operating Temperature-30 to +80°C (assuming no icing or condensation)
Ambient Operating Humidity45 to 85% RH
WeightApprox. 70 g
Part Number
G3B-205S DC4-30
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to Ship

MYR 231.00

1 Piece(s) 1 Day(s)

Loading...

  1. 1
 

Basic Information

Application SSR Terminal shape Socket / plug-in Contact rated current (minimum value for AC and DC)(A) 0.1
Dimension height(mm) 52.5 Dimension width(mm) 35 Dimension depth(mm) 35
Insulation method Photo coupler Zero cross function Available Operation Indicator Lamp Available
Input rated voltage(V) DC5 to 24 Applicable output load(A)/(V) AC100 to 240V/5A