Control/Instrumentation Cables(Logarithm:7P)

Control and instrumentation cables are used for device controls and signal transmissions to and from terminal devices. Control cables are mainly used to control devices in plants and factories. For this reason, insulated vinyl sheath cables with PVC and polyethylene insulation are usually used for their highly flame retardant properties and excellent oil resistance, weather resistance and water resistance. Instrumentation cables are used in a wide range of applications including transmitting computer signals, electronic controls for industrial equipment, etc. Insulated vinyl sheath cables with polyethylene insulators are often used for their capacitance and noise reduction characteristics. The cables are selected for length and number of pairs, but other specific properties should also be considered, such as abrasion resistance and chemical resistance.
Days to Ship
  • All
  • 1 Day(s) or Less
  • 2 Day(s) or Less
  • 3 Day(s) or Less
  • 4 Day(s) or Less
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • 40 Day(s) or Less
  • 45 Day(s) or Less
  1. 1
Brand
Product Series
Days to Ship
Specifications
Overall Length(m)
Specified Length(m)
Conductor Cross Section(mm2)
AWG size(AWG)
Number Of Cores(Core)
Logarithm
Finished outer diameter(mm)
Rated Voltage
Shield
Properties
Representative Standard
Sheath (outer coating) color
Grounding Wire
Sheath (outer coating) material
Insulation body materials

    Polyethylene Insulation Vinyl Sheath Instrumentation Cable J-KNPEV-SB

      BIO Highly Flame Retardant NEC Standard Cable (Non-Shield)

        Twisted Pair Instrumentation Cable

          NA3VCSB UL Standard with Shield

            NAVC UL Standard

              KVC-36SBT

                NA3VC UL Standard

                  NAVCSB UL Standard with Shield

                    NAKVVSB 100 V or less with Shield

                      KVC36SB UL Standard with Shield

                      Brand

                      NIHON ELECTRIC WIRE & CABLE

                      BANDO DENSEN

                      TACHII ELECTRIC WIRE

                      MISUMI_Test

                      MISUMI_Test

                      KURAMO ELECTRIC

                      MISUMI_Test

                      MISUMI_Test

                      MISUMI_Test

                      MISUMI_Test

                      Product Series

                      Polyethylene Insulation Vinyl Sheath Instrumentation Cable J-KNPEV-SB

                      BIO Highly Flame Retardant NEC Standard Cable (Non-Shield)

                      Twisted Pair Instrumentation Cable

                      NA3VCSB UL Standard with Shield

                      NAVC UL Standard

                      KVC-36SBT

                      NA3VC UL Standard

                      NAVCSB UL Standard with Shield

                      NAKVVSB 100 V or less with Shield

                      KVC36SB UL Standard with Shield

                      Days to Ship 5 Day(s) or more 2 Day(s) or more 45 Day(s) or more 2 Day(s) or more 2 Day(s) or more 4 Day(s) or more 2 Day(s) or more 2 Day(s) or more 2 Day(s) or more 2 Day(s) or more
                      Specifications
                            • VW-1
                            • ULAWM
                            • Oil-Resistant
                            • Strand Wire
                            • Single Shield
                            • Twisted Pair
                            • 300 V
                            • VW-1
                            • ULAWM
                            • Oil-Resistant
                            • Strand Wire
                            • Twisted Pair
                            • Small Diameter
                            • 150 V
                              • VW-1
                              • ULAWM
                              • Oil-Resistant
                              • Strand Wire
                              • Twisted Pair
                              • 300 V
                              • VW-1
                              • ULAWM
                              • Oil-Resistant
                              • Strand Wire
                              • Single Shield
                              • Twisted Pair
                              • Small Diameter
                              • 150 V
                              • Oil-Resistant
                              • Strand Wire
                              • Single Shield
                              • Twisted Pair
                              • Less than 100 V
                              • c-UL
                              • VW-1
                              • FT-1
                              • ULAWM
                              • Oil-Resistant
                              • Strand Wire
                              • Single Shield
                              • Twisted Pair
                              • Less than 100 V
                              Overall Length(m)48 ~ 66501 ~ 10020 ~ 834 ~ 100678 ~ 975 ~ 9127 ~ 669 ~ 67
                              Specified Length(m)----------
                              Conductor Cross Section(mm2)0.5 ~ 2-0.30.2 ~ 0.50.12 ~ 0.30.50.30.12 ~ 0.50.2 ~ 0.50.2 ~ 0.3
                              AWG size(AWG)14 ~ 20262221 ~ 2523 ~ 27202321 ~ 2721 ~ 2523 ~ 25
                              Number Of Cores(Core)14-14--14----
                              Logarithm7P7P7P7P7P7P7P7P7P7P
                              Finished outer diameter(mm)13 ~ 2078.97.3 ~ 9.46.6 ~ 8.310.587.1 ~ 9.97.4 ~ 10.17.7 ~ 9.5
                              Rated Voltage-300VOther300VFor Low Current CircuitsFor Low Current Circuits300VFor Low Current CircuitsFor Low Current CircuitsFor Low Current Circuits
                              ShieldAvailableNAAvailableAvailableNAAvailableNAAvailableAvailableAvailable
                              PropertiesOil Resistance / Heat-ResistanceHeat-ResistanceOil Resistance / Heat-ResistanceOil ResistanceOil ResistanceOil ResistanceOil ResistanceOil ResistanceOil ResistanceOil Resistance
                              Representative Standard-UL / CSA(c-UL)UL / CSA(c-UL)ULULUL / CSA(c-UL)ULUL-UL / CSA(c-UL)
                              Sheath (outer coating) colorBlackBlackGray00033 / Blue00033 / BlueBlack00033 / Blue00033 / Blue00033 / BlueBlack
                              Grounding WireNA-Other--Other----
                              Sheath (outer coating) material-PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)
                              Insulation body materialsPolyethylene-BasedPVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)