(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 9:00 19/4/2026 to 7:00 (MYT) 20/4/2026. We apologize for the inconvenience.
  • [Notice] Japan & China Golden Week holidays will start from 29 April to 6 May 2026. Kindly expect longer response from suppliers and possible delivery delay due to high volume of shipments after holiday. Early order placement is recommended. More details
  • [Announcement] MISUMI Malaysia website new user interface. Clearer navigation, easy product search and more. Explore now! May contact us at (60) 3 7890 6399 for any inquiries.

Control/Instrumentation Cables(Logarithm:12P)

Control and instrumentation cables are used for device controls and signal transmissions to and from terminal devices. Control cables are mainly used to control devices in plants and factories. For this reason, insulated vinyl sheath cables with PVC and polyethylene insulation are usually used for their highly flame retardant properties and excellent oil resistance, weather resistance and water resistance. Instrumentation cables are used in a wide range of applications including transmitting computer signals, electronic controls for industrial equipment, etc. Insulated vinyl sheath cables with polyethylene insulators are often used for their capacitance and noise reduction characteristics. The cables are selected for length and number of pairs, but other specific properties should also be considered, such as abrasion resistance and chemical resistance.
Days to Ship
  • All
  • 1 Day(s) or Less
  • 2 Day(s) or Less
  • 3 Day(s) or Less
  • 4 Day(s) or Less
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • 40 Day(s) or Less
  • 45 Day(s) or Less
  1. 1
Brand
Product Series
Days to Ship
Specifications
Overall Length(m)
Specified Length(m)
Conductor Cross Section(mm2)
AWG size(AWG)
Number Of Cores(Core)
Logarithm
Finished outer diameter(mm)
Rated Voltage
Shield
Properties
Representative Standard
Sheath (outer coating) color
Grounding Wire
Sheath (outer coating) material
Insulation body materials

    BIO Highly Flame Retardant NEC Standard Cable (Non-Shield)

      Twisted Pair Instrumentation Cable

        NA3VCSB UL Standard with Shield

          NA3VC UL Standard

            NAKVVSB 100 V or less with Shield

              KVC36SB UL Standard with Shield

              Brand

              BANDO DENSEN

              TACHII ELECTRIC WIRE

              MISUMI_Test

              MISUMI_Test

              MISUMI_Test

              MISUMI_Test

              Product Series

              BIO Highly Flame Retardant NEC Standard Cable (Non-Shield)

              Twisted Pair Instrumentation Cable

              NA3VCSB UL Standard with Shield

              NA3VC UL Standard

              NAKVVSB 100 V or less with Shield

              KVC36SB UL Standard with Shield

              Days to Ship 2 Day(s) or more 45 Day(s) or more 2 Day(s) or more 2 Day(s) or more 2 Day(s) or more 2 Day(s) or more
              Specifications
                  • VW-1
                  • ULAWM
                  • Oil-Resistant
                  • Strand Wire
                  • Single Shield
                  • Twisted Pair
                  • 300 V
                  • VW-1
                  • ULAWM
                  • Oil-Resistant
                  • Strand Wire
                  • Twisted Pair
                  • 300 V
                  • Oil-Resistant
                  • Strand Wire
                  • Single Shield
                  • Twisted Pair
                  • Less than 100 V
                  • c-UL
                  • VW-1
                  • FT-1
                  • ULAWM
                  • Oil-Resistant
                  • Strand Wire
                  • Single Shield
                  • Twisted Pair
                  • Less than 100 V
                  Overall Length(m)81 ~ 1002 ~ 6714 ~ 4037 ~ 8110 ~ 75
                  Specified Length(m)------
                  Conductor Cross Section(mm2)-0.30.2 ~ 0.30.2 ~ 0.30.2 ~ 0.30.3
                  AWG size(AWG)222223 ~ 2523 ~ 2523 ~ 2523
                  Number Of Cores(Core)-24----
                  Logarithm12P12P12P12P12P12P
                  Finished outer diameter(mm)11.311.59.3 ~ 10.88.8 ~ 10.39.7 ~ 11.312
                  Rated Voltage300VOther300V300VFor Low Current CircuitsFor Low Current Circuits
                  ShieldNAAvailableAvailableNAAvailableAvailable
                  PropertiesHeat-ResistanceOil Resistance / Heat-ResistanceOil ResistanceOil ResistanceOil ResistanceOil Resistance
                  Representative StandardUL / CSA(c-UL)UL / CSA(c-UL)ULUL-UL / CSA(c-UL)
                  Sheath (outer coating) colorBlackGray00033 / Blue00033 / Blue00033 / BlueBlack
                  Grounding Wire-Other----
                  Sheath (outer coating) materialPVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)
                  Insulation body materialsPVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)

                  Loading...

                  1. 1

                  Related Categories to Control/Instrumentation Cables