(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 9:00 19/4/2026 to 7:00 (MYT) 20/4/2026. We apologize for the inconvenience.
  • [Notice] Japan & China Golden Week holidays will start from 29 April to 6 May 2026. Kindly expect longer response from suppliers and possible delivery delay due to high volume of shipments after holiday. Early order placement is recommended. More details
  • [Announcement] MISUMI Malaysia website new user interface. Clearer navigation, easy product search and more. Explore now! May contact us at (60) 3 7890 6399 for any inquiries.

Control/Instrumentation Cables(Properties:Heat-Resistance)

Control and instrumentation cables are used for device controls and signal transmissions to and from terminal devices. Control cables are mainly used to control devices in plants and factories. For this reason, insulated vinyl sheath cables with PVC and polyethylene insulation are usually used for their highly flame retardant properties and excellent oil resistance, weather resistance and water resistance. Instrumentation cables are used in a wide range of applications including transmitting computer signals, electronic controls for industrial equipment, etc. Insulated vinyl sheath cables with polyethylene insulators are often used for their capacitance and noise reduction characteristics. The cables are selected for length and number of pairs, but other specific properties should also be considered, such as abrasion resistance and chemical resistance.
Days to Ship
  • All
  • 1 Day(s) or Less
  • 2 Day(s) or Less
  • 3 Day(s) or Less
  • 4 Day(s) or Less
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • 40 Day(s) or Less
  • 45 Day(s) or Less
  1. 1
Brand
Product Series
Days to Ship
Overall Length(m)
Specified Length(m)
Conductor Cross Section(mm2)
AWG size(AWG)
Number Of Cores(Core)
Logarithm
Finished outer diameter(mm)
Rated Voltage
Shield
Properties
Representative Standard
Sheath (outer coating) color
Grounding Wire
Sheath (outer coating) material
Insulation body materials

    Polyethylene Insulation Vinyl Sheath Instrumentation Cable J-KNPEV-SB

      BIO Highly Flame Retardant NEC Standard Cable (Non-Shield)

        Instrumentation Cable, FKEV-SB

          Twisted Pair Instrumentation Cable

            BIOS Highly Flame Retardant NEC Standard Cable (Shielded)

              Twisted Layer Instrumentation Cable

                SCIC Series

                  Shielded Twisted Pair Multi-Core Cable, MSCKF Series

                    Thermocouple K Type - KCA(WX)-2-H-GGBF Series - New Color Type

                      Compensating Cable, Thermocouple K Type, KX-1-H-GGBF-BT Series, New Color Type

                        Compensating Lead Cable - Thermocouple N Type - NX-1-H-GGBF Series

                        Brand

                        NIHON ELECTRIC WIRE & CABLE

                        BANDO DENSEN

                        FUJI ELECTRIC WIRE INDUSTRIES

                        TACHII ELECTRIC WIRE

                        BANDO DENSEN

                        TACHII ELECTRIC WIRE

                        NAGAOKA ELECTRIC WIRE

                        KANEKO CORD

                        FUKUDEN

                        FUKUDEN

                        FUKUDEN

                        Product Series

                        Polyethylene Insulation Vinyl Sheath Instrumentation Cable J-KNPEV-SB

                        BIO Highly Flame Retardant NEC Standard Cable (Non-Shield)

                        Instrumentation Cable, FKEV-SB

                        Twisted Pair Instrumentation Cable

                        BIOS Highly Flame Retardant NEC Standard Cable (Shielded)

                        Twisted Layer Instrumentation Cable

                        SCIC Series

                        Shielded Twisted Pair Multi-Core Cable, MSCKF Series

                        Thermocouple K Type - KCA(WX)-2-H-GGBF Series - New Color Type

                        Compensating Cable, Thermocouple K Type, KX-1-H-GGBF-BT Series, New Color Type

                        Compensating Lead Cable - Thermocouple N Type - NX-1-H-GGBF Series

                        Days to Ship 5 Day(s) or more 2 Day(s) or more 3 Day(s) or more 2 Day(s) or more 2 Day(s) or more 45 Day(s) or more 2 Day(s) or more 2 Day(s) or more 6 Day(s) or more 6 Day(s) or more 6 Day(s) or more
                        Overall Length(m)8 ~ 768 ~ 50381 ~ 10059334 ~ 8382 ~ 997110 ~ 10010 ~ 100
                        Specified Length(m)-----------
                        Conductor Cross Section(mm2)0.2 ~ 2-1.250.2 ~ 0.3-0.30.180.0881.251.250.5
                        AWG size(AWG)14 ~ 2420 ~ 26-22 ~ 2426222528---
                        Number Of Cores(Core)2 ~ 40-612 ~ 30-624 ~ 5036222
                        Logarithm1P ~ 20P7P ~ 12P36P ~ 15P2P--18P111
                        Finished outer diameter(mm)7.5 ~ 207 ~ 13.412.57.4 ~ 12.66.16.59.5 ~ 12.5-3.0x5.13.6x5.72.1x3.7
                        Rated Voltage-300VOtherOther300VOtherFor Low Current Circuits300V---
                        ShieldAvailableNAAvailableAvailableAvailableAvailableAvailableAvailableNAAvailableNA
                        PropertiesHeat-ResistanceHeat-ResistanceHeat-ResistanceHeat-ResistanceHeat-ResistanceHeat-ResistanceHeat-ResistanceHeat-ResistanceHeat-ResistanceHeat-ResistanceHeat-Resistance
                        Representative Standard-UL / CSA(c-UL)-UL / CSA(c-UL)UL / CSA(c-UL)UL / CSA(c-UL)-UL---
                        Sheath (outer coating) colorBlackBlackGrayGrayBlackBlackOtherWhiteGreenGreenOther
                        Grounding WireNA-OtherOther-OtherNAOtherNANANA
                        Sheath (outer coating) material-PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)OtherPVC (Polyvinyl Chloride)OtherOtherOther
                        Insulation body materialsPolyethylene-BasedPVC (Polyvinyl Chloride)Polyethylene-BasedPVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)OtherPVC (Polyvinyl Chloride)OtherOtherOther

                        Loading...

                        1. 1

                        Related Categories to Control/Instrumentation Cables