Electromagnetic switch for 24 VDC. World's Longest Switching Life


Part Number
Configured Part Number is shown.

| Frame Size (AF) | Coil Voltage | Auxiliary Contact | Motor Capacity (KW) | Thermal Relay Model | Setting Range (A) | Model |
| 6 | 24 VDC | 1a | 0.05 | SMR-12-0.52 | 0.4 ~ 0.63 | KHK6-DC24V-0.52 |
| 0.1 | SMR-12-0.82 | 0.63 ~ 1 | KHK6-DC24V-0.82 | |||
| 0.2 | SMR-12-1.3 | 1 ~ 1.6 | KHK6-DC24V-1.3 | |||
| 0.4 | SMR-12-2.1 | 1.6 ~ 2.5 | KHK6-DC24V-2.1 | |||
| 0.75 | SMR-12-3.3 | 2.5 ~ 4 | KHK6-DC24V-3.3 | |||
| 1 | SMR-12-5 | 4 ~ 6 | KHK6-DC24V-5 | |||
| 1.5 | SMR-12-6.5 | 5 ~ 8 | KHK6-DC24V-6.5 | |||
| 1.5 | SMR-12-7.5 | 6 ~ 9 | KHK6-DC24V-7.5 | |||
| 2.2 | SMR-12-8.5 | 7 ~ 10 | KHK6-DC24V-8.5 | |||
| 9 | 1a1b | 0.05 | SMR-32-0.52 | 0.4 ~ 0.63 | KHK9-DC24V-0.52 | |
| 0.1 | SMR-32-0.82 | 0.63 ~ 1 | KHK9-DC24V-0.82 | |||
| 0.2 | SMR-32-1.3 | 1 ~ 1.6 | KHK9-DC24V-1.3 | |||
| 0.4 | SMR-32-2.1 | 1.6 ~ 2.5 | KHK9-DC24V-2.1 | |||
| 0.75 | SMR-32-3.3 | 2.5 ~ 4 | KHK9-DC24V-3.3 | |||
| 1 | SMR-32-5 | 4 ~ 6 | KHK9-DC24V-5 | |||
| 1.5 | SMR-32-6.5 | 5 ~ 8 | KHK9-DC24V-6.5 | |||
| 1.5 | SMR-32-7.5 | 6 ~ 9 | KHK9-DC24V-7.5 | |||
| 2.2 | SMR-32-8.5 | 7 ~ 10 | KHK9-DC24V-8.5 | |||
| 3.7 | SMR-32-11 | 9 ~ 13 | KHK9-DC24V-11 | |||
| 3.7 | SMR-32-15 | 12 ~ 18 | KHK9-DC24V-15 | |||
| 5.5 | SMR-32-19 | 16 ~ 22 | KHK9-DC24V-19 | |||
| 5.5 | SMR-32-21.5 | 18 ~ 25 | KHK9-DC24V-21.5 | |||
| 7.5 | SMR-32-27 | 22 ~ 32 | KHK9-DC24V-27 | |||
| 13 | 1a1b | 0.05 | SMR-32-0.52 | 0.4 ~ 0.63 | KHK12-DC24V-0.52 | |
| 0.1 | SMR-32-0.82 | 0.63 ~ 1 | KHK12-DC24V-0.82 | |||
| 0.2 | SMR-32-1.3 | 1 ~ 1.6 | KHK12-DC24V-1.3 | |||
| 0.4 | SMR-32-2.1 | 1.6 ~ 2.5 | KHK12-DC24V-2.1 | |||
| 0.75 | SMR-32-3.3 | 2.5 ~ 4 | KHK12-DC24V-3.3 | |||
| 1 | SMR-32-5 | 4 ~ 6 | KHK12-DC24V-5 | |||
| 1.5 | SMR-32-6.5 | 5 ~ 8 | KHK12-DC24V-6.5 | |||
| 1.5 | SMR-32-7.5 | 6 ~ 9 | KHK12-DC24V-7.5 | |||
| 2.2 | SMR-32-8.5 | 7 ~ 10 | KHK12-DC24V-8.5 | |||
| 3.7 | SMR-32-11 | 9 ~ 13 | KHK12-DC24V-11 | |||
| 3.7 | SMR-32-15 | 12 ~ 18 | KHK12-DC24V-15 | |||
| 5.5 | SMR-32-19 | 16 ~ 22 | KHK12-DC24V-19 | |||
| 5.5 | SMR-32-21.5 | 18 ~ 25 | KHK12-DC24V-21.5 | |||
| 7.5 | SMR-32-27 | 22 ~ 32 | KHK12-DC24V-27 | |||
| 18 | 1a1b | 0.05 | SMR-32-0.52 | 0.4 ~ 0.63 | KHK18-DC24V-0.52 | |
| 0.1 | SMR-32-0.82 | 0.63 ~ 1 | KHK18-DC24V-0.82 | |||
| 0.2 | SMR-32-1.3 | 1 ~ 1.6 | KHK18-DC24V-1.3 | |||
| 0.4 | SMR-32-2.1 | 1.6 ~ 2.5 | KHK18-DC24V-2.1 | |||
| 0.75 | SMR-32-3.3 | 2.5 ~ 4 | KHK18-DC24V-3.3 | |||
| 1 | SMR-32-5 | 4 ~ 6 | KHK18-DC24V-5 | |||
| 1.5 | SMR-32-6.5 | 5 ~ 8 | KHK18-DC24V-6.5 | |||
| 1.5 | SMR-32-7.5 | 6 ~ 9 | KHK18-DC24V-7.5 | |||
| 2.2 | SMR-32-8.5 | 7 ~ 10 | KHK18-DC24V-8.5 | |||
| 3.7 | SMR-32-11 | 9 ~ 13 | KHK18-DC24V-11 | |||
| 3.7 | SMR-32-15 | 12 ~ 18 | KHK18-DC24V-15 | |||
| 5.5 | SMR-32-19 | 16 ~ 22 | KHK18-DC24V-19 | |||
| 5.5 | SMR-32-21.5 | 18 ~ 25 | KHK18-DC24V-21.5 | |||
| 7.5 | SMR-32-27 | 22 ~ 32 | KHK18-DC24V-27 | |||
| 22 | 1a1b | 0.05 | SMR-32-0.52 | 0.4 ~ 0.63 | KHK22-DC24V-0.52 | |
| 0.1 | SMR-32-0.82 | 0.63 ~ 1 | KHK22-DC24V-0.82 | |||
| 0.2 | SMR-32-1.3 | 1 ~ 1.6 | KHK22-DC24V-1.3 | |||
| 0.4 | SMR-32-2.1 | 1.6 ~ 2.5 | KHK22-DC24V-2.1 | |||
| 0.75 | SMR-32-3.3 | 2.5 ~ 4 | KHK22-DC24V-3.3 | |||
| 1 | SMR-32-5 | 4 ~ 6 | KHK22-DC24V-5 | |||
| 1.5 | SMR-32-6.5 | 5 ~ 8 | KHK22-DC24V-6.5 | |||
| 1.5 | SMR-32-7.5 | 6 ~ 9 | KHK22-DC24V-7.5 | |||
| 2.2 | SMR-32-8.5 | 7 ~ 10 | KHK22-DC24V-8.5 | |||
| 3.7 | SMR-32-11 | 9 ~ 13 | KHK22-DC24V-11 | |||
| 3.7 | SMR-32-15 | 12 ~ 18 | KHK22-DC24V-15 | |||
| 5.5 | SMR-32-19 | 16 ~ 22 | KHK22-DC24V-19 | |||
| 5.5 | SMR-32-21.5 | 18 ~ 25 | KHK22-DC24V-21.5 | |||
| 7.5 | SMR-32-27 | 22 ~ 32 | KHK22-DC24V-27 |
| Rated Voltage | Rated Current | |
| Auxiliary Contact Capacity | AC120V | 6A |
| AC240V | 3A | |
| AC380V | 1.9A | |
| AC480V | 1.5A | |
| AC500V | 1.4A | |
| AC600V | 1.2A | |
| DC125V | 1.1A | |
| DC250V | 0.55A | |
| DC400V | 0.31A | |
| DC500V | 0.27A | |
| DC600V | 0.2A |
| Model | KHK6 | KHK9 | |
| KHK12 | |||
| KHK18 | |||
| KHK22 | |||
| Operation Voltage | 24V | ||
| Clamping Voltage | Pickup | 70 ~ 110% | |
| Dropout | 10 ~ 30% | ||
| Coil Power Consumption | Inrush Current (VA) | 9 | 9 |
| 24 VDC | Rated Power (VA) | 9 | 9 |
| Coil Current | (A) | 0.4 | 0.4 |
| Operating Time | Closed (ms) | 35...50 | 35...50 |
| Open (ms) | 4...19 | 4...19 | |
| Ambient Temperature | Reference 20°C, -10°C ~ 40°C |
| (Maximum 35°C daily average air temperature, maximum 25°C annual average air temperature) | |
| Maximum Board Internal Temperature | 55°C |
| Take care, as operational characteristics of electromagnetic contacts and thermal relays can be affected by the ambient temperature. | |
| Relative Humidity | 45 ~ 85% RH, no condensation or freezing. |
| Altitude | 2,000 m or lower |
| Vibration | 10 ~ 55 Hz 19.6 m / s2 or lower |
| Impact | 49 m / s2 or lower |
| Atmosphere | Excessive amount of dust, smoke, corrosive gases, flammable gas, moisture, or salt must not be present. Extended use in sealed conditions may lead to possible contact defects. |

| Part Number |
|---|
| KHK12-DC24V-0.52 |
| KHK12-DC24V-3.3 |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Motor Capacity VAC 200–220 Class (kW/A) | Motor capacity AC 200 V (kW/A) | Setting range (A) |
|---|---|---|---|---|---|---|---|
MYR 251.36 | 1 Piece(s) | Available | 2 Day(s) or more | 0.05 | 0.05 | 0.4 ~ 0.63 | |
MYR 251.36 | 1 Piece(s) | Available | 2 Day(s) or more | 0.75 | 0.75 | 2.5 ~ 4 |
Loading...
Electromagnetic Switch
Electromagnetic Switch
| Frame Size | 18AF | 22AF | 40AF | 65AF | ||||
|---|---|---|---|---|---|---|---|---|
| Model | KHK6 | KHK9 | KHK12 | KHK18 | KHK22 | KHK32 | KHK50 | KHK65 |
| Number of Phases | 3 | 3 | 3 | 3 | ||||
| Rated Voltage | 690 V | 690 V | 690 V | 690 V | ||||
| Rated Insulation Voltage | 690 V | 690 V | 1,000 V | 1,000 V | ||||
| Rated Frequency | 50 / 60 Hz | 50 / 60 Hz | 50 / 60 Hz | 50 / 60 Hz | ||||
| Rated Impulse Voltage | 6 KV | 6 KV | 8 KV | 8 KV | ||||
| Switching Frequency (times / hour), AC Class 3 | 1,800 | 1,800 | 1,800 | 1,800 | ||||
| Mechanical Life (10,000 times) | 1,500 | 1,500 | 1,200 | 1,200 | ||||
| Electrical Life (10,000 times) | 250 | 250 | 200 | 200 | ||||
| AC - Class 1 A | 25 | 25 | 25 | 32 | 40 | 50 | 70 | 100 |
| AC - Class 3 200 / 240 V KW | 2.2 | 2.5 | 3.5 | 4.5 | 5.5 | 7.5 | 15 | 18.5 |
| A | 9 | 11 | 13 | 18 | 22 | 32 | 55 | 65 |
| 380 / 440 V KW | 3 | 4 | 5.5 | 7.5 | 11 | 15 | 22 | 30 |
| A | 7 | 9 | 12 | 18 | 22 | 32 | 50 | 65 |
| 500 / 550 V KW | 3 | 4 | 7.5 | 7.5 | 15 | 18.5 | 30 | 33 |
| A | 6 | 7 | 12 | 13 | 20 | 28 | 43 | 60 |
| 690 V KW | 3 | 4 | 7.5 | 7.5 | 15 | 18.5 | 30 | 33 |
| A | 4 | 6 | 9 | 9 | 18 | 20 | 28 | 35 |
| UL Rated, Continuous Current, A | 25 | 25 | 25 | 40 | 40 | 50 | 70 | 100 |
| Single Phase 110 ~ 120 V | 0.5 | 0.5 | 0.75 | 1 | 2 | 2 | 3 | 5 |
| 220 ~ 240 V | 1.5 | 1.5 | 2 | 3 | 3 | 5 | 10 | 15 |
| Three Phase 200 ~ 208 V | 2 | 2 | 3 | 5 | 7.5 | 7.5 | 20 | 25 |
| 220 ~ 240 V | 3 | 3 | 5 | 7.5 | 10 | 10 | 25 | 30 |
| 440 ~ 480 V | 5 | 5 | 7.5 | 10 | 15 | 20 | 40 | 50 |
| 550 ~ 600 V | 7.5 | 7.5 | 10 | 15 | 20 | 25 | 50 | 60 |
| Coil Voltage AC Weight Kg | 0.43 | 0.54 | 0.72 | 1.36 | 1.38 | |||
| Coil Voltage DC Weight, Kg | 0.6 | 0.68 | 0.94 | 1.61 | 1.63 | |||
| Ambient Temperature | Standard temperature at 20°C, -10°C ~ 40°C |
|---|---|
| (Maximum Daily Average Ambient Temperature 35°C, Maximum Annual Average Ambient Temperature 25°C) | |
| Maximum Internal Panel Temperature | 55°C |
| Note that the operating properties of the electromagnetic connector and thermal relay are influenced by ambient temperature. | |
| Relative Humidity | 45 ~ 85% RH, no condensation or freezing. |
| Altitude | 2,000 m or lower |
| Vibration | 10 ~ 55 Hz 19.6 m/s2 or lower |
| Impact | 49 m/s2 or lower |
| Ambient Atmosphere | The ambient atmosphere must not contain excessive dust, smoke, corrosive or combustible gas, moisture, or salt content. Further, prolonged operation while sealed may cause problems such as contact failure. |
| Operating Method | Irreversible type | Coil rated voltage(V) | DC24 | Number of Poles | 3 |
|---|---|---|---|---|---|
| Auxiliary Contact | 1a1b | Representative Standard | CE | Dimension length(mm) | 129.9 |
| Dimension width(mm) | 45 | Dimension thickness(mm) | 117.7 | Other standards (IEC) | ○ |
| Other standards (KEMA) | ○ | Rated current(A) | 12 |

MISUMI_Test
Standard Price : MYR 427.14
Days to Ship : 2 Day(s) or more
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy