MAST-MVVS 100 V or Less Shielded Wire

MAST-MVVS 100 V or Less Shielded Wire

For Weak Current Circuit General-purpose Signals Cable with Shield

  • Strand Wire
  • Single Shield

MAST-MVVS 100 V or Less Shielded Wire:Related Image
For Weak Current Circuit General-purpose Signals Cable

Color and softness may vary slightly due to manufacturer changes.

Part Number

Configured Part Number is shown.

MAST-MVVS-0.3-16-72

Specifications

MAST-MVVS 100 V or Less Shielded Wire:Related Image
Model
Section Area (mm2)
Number of Cores
Total Length
or
Specified Length
MAST-MVVS
0.3
2
1
~
100
(Specify 1 m
Increments)
3
4
5
6
8
10
16
0.5
2
3
4
6
10
0.75
2
3
4
1.25
2

Be sure to read the following precautions when you place an order.
* Length in "m" is included in our part numbers.Always specify quantity as number of units, not as meters.
* This price is as of January 2013.
* Check the indications for number of cores, pair number, core / pair number, and pair number / core when ordering(Refer to the specifications table for number of wire cores.) 1P (1 PS) is "× 2-core".

More Information

MAST-MVVS 100 V or Less Shielded Wire:Related ImageMAST-MVVS 100 V or Less Shielded Wire:Related Image
Specifications
ModelSection Area
(mm2)
Number of Cores *AWG
Size
Reference *
Strand
Structure
(See Figure)
Wire Core
Count
Finish
Outer Diameter
(mm)
Estimated
Mass
kg / km
Electrical PropertiesConductorInsulationWire Core
Outer Diameter
Approx. (mm)
SheathSpecification
Allowable Current
A (30°C) *
Conductor Resistance
Ω/ km (20°C)
Insulation Properties
MΩ/ km (20°C)
Withstand Voltage
V/Min
Structure
Strands / mm
Outer Diameter
Approx. (mm)
Plating *Thickness
(mm)
Material *Thickness
(mm)
Material *

MAST-MVVS

0.3222Core / Layer Stranding25.0365.463.210050017/0.150.71N/A0.3PVC1.30.9PVC
335.2414.7
4 45.5494.2
556.2583.81
666.6663.6
887.0773.1
10107.9943.0
16168.81292.2
0.522025.4437.537.820/0.180.930.31.50.9
335.6516.5
446.0605.8
667.2844.91
10108.71254.0
0.7521825.8519.825.130/0.181.140.31.70.9
336.0618.5
446.5757.6
1.2521627.07614.415.150/0.181.470.42.30.9

* Please note that when the indicated Core / Pair is 1P (1PS), the number of wire cores will be "× 2-core".
* Allowable current is to be used only as a reference value and is not guaranteed.
How to View Materials
[Plating] Tin… Tin Plated Annealed Copper Wire
[Materials] PVC… Polyvinyl Chloride; PE… Polyethylene-based Material
P… Polyester-based Material; Fluorine… Various Fluorine Resins; *…Others
* Color and softness may vary slightly due to manufacturer changes.
* 7 For the outer diameter size of cables, wire sheath (coat), etc., refer to "Finished Outer Diameter" in the table above.
* 8 The main difference from the MVVS-A series is the manufacturer. The specifications are extremely similar: it is an equivalent product. For detailed specification differences, check the Specification Table.
Current Reduction Factor
・ At Ambient Temperature
Ambient Temperature (°C)3540455055
Current Reduction Factor0.910.820.710.580.41
Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30°C or above, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current value when the ambient temperature is 40°C, MVVS 0.3 mm2 2-core:
2.0×0.82 = 1.64 (A)
Wire Core Identification Table
Wire Core No.12345678910111213141516
Insulator ColorBlackWhiteRedGreenYellowBrownBlueGrayOrangeLight BluePinkYoung LeafPurpleWhiteWhiteWhite
Color of Identification LineBlackRedGreen
Part Number
MAST-MVVS-0.3-16-72
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to Ship

MYR 688.48

1 Piece(s) 2 Day(s) or more

Loading...

  1. 1

Basic Information

Overall Length(m) 72 Conductor Cross Section(mm2) 0.3 AWG size(AWG) 22
Number Of Cores(Core) 16 Finished outer diameter(mm) 9.6 Rated Voltage Less than 100 V
Shield Present Sheath (outer coating) color Black Sheath (outer coating) material PVC
Insulation body materials PVC Power supply/signal For signals

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7960 8499 / FAX:(60) 3 7960 7499
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)