· Solid state contact for 3-phase motors that can be used with protection coordinated contact sensing and thermal relays.
· UL/CSA standard acquired.
· Use with both DIN rail mounting and screw mounting.
· Heat sink integrated compact construction (W80 × H100 × D100 mm).
· Built-in snubber circuit and varistor.
· Built-in operation display lamp.
· 2 element type also part of a series.
Japanese Only
Part Number
Configured Part Number is shown.
G3J-205BL DC12-24

Simple Type external appearance

Simple Type external appearance

G3J-205BL/G3J-205BL-2/G3J-211BL dimensional outline drawing, Units: mm

G3J-205BL/G3J-205BL-2/G3J-211BL dimensional outline drawing, Units: mm

G3J-205BL/G3J-205BL-2/G3J-211BL mounting hole machining dimensions, Units: mm
| Type | DC Input Type | AC Input Type |
|---|---|---|
| Rated Operating Voltage | 12 to 24 V DC | 100 to 240 V AC (50/60 Hz) |
| Operating Voltage Range | 9.6 to 26.4 V DC | 75 to 264 V AC (50/60 Hz) |
| Rated Input Current (Impedance) | 15 mA max. (12 to 24 V DC) | 36 kΩ ±20% (100 to 240 V AC) |
| Operating Voltage | 9.6 V DC max. | 75 V AC max. |
| Release Voltage | 3.6 V DC min. | 20 V AC max. |
| Format | Model G3J-211BL | Model G3J-205BL Model G3J-205BL-2 | |
|---|---|---|---|
| Rated Operating Voltage | 100 to 240 V AC (50/60 Hz) | ||
| Load Voltage Range | 75 to 264 V AC (50/60 Hz) | ||
| Rated Carry Current *1 | 11.1 A (at 40°C) | 4.8 A (at 40°C) | |
| Minimum Load Current | 0.1 A | ||
| Peak-Value Current Resistivity | 350 A (60 Hz, 1 cycle) | 150 A (60 Hz, 1 cycle) | |
| Closed Current (Effective Value) | AC 3 | 111 A | 48 A |
| AC 4 | 133.2 A | 57.6 A | |
| Breaking Current (Effective Value) | AC 3 | 88.8 A | 38.4 A |
| AC 4 | 111 A | 48 A | |
| Applied Load | Three-Phase Inductive Motor (AC3, AC4, AC35-a) | 200 to 220 V AC 2.2 kW (11.1 A) | 200 to 220 V AC 0.75 kW (4.8 A) |
| Satisfies switching test conditions of AC3, AC4, and AC53-a. | |||
| Single Phase Motor (AC3) *2 | 100 V AC 0.4 kW (11.1 A) 200 V AC 0.75 kW (8.8 A) | 100 V AC 0.1 kW (5.1 A) *3 200 V AC 0.4 kW (5.5 A) | |
| Resistive Load (AC1) | 100 to 240 V AC 11.1 A | 100 to 240 V AC 4.8 A | |
| Type | DC Input Type | AC Input Type |
|---|---|---|
| Operating Time | 1 ms max. | 50 ms max. |
| Release Time | 5/6 of load power source cycle + 1 ms max. | 3/2 of load power source cycle + 1 ms max. |
| Output ON Voltage Drop | 1.6 V (RMS) max. | |
| Leakage Current * | 10 mA max. (at 200 V AC) | |
| Insulation Resistance | 100 MΩ min. (with 500 V ohmmeter) | |
| Dielectric Strength | 2,500 V AC 50/60 Hz 1 min | |
| Vibration | 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) | |
| Shock | 294 m/s2 | |
| Storage Temperature | −30 to +70°C (assuming no icing or condensation) | |
| Ambient Operating Temperature | −20 to +60°C (assuming no icing or condensation) | |
| Ambient Operating Humidity | 45 to 85% RH | |
| Weight | Approx. 700 g | |
* With 2-element types, the S-phase leakage current will be larger by a factor of approximately √3.
| Part Number |
|---|
| G3J-205BL DC12-24 |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship |
|---|---|---|---|---|
MYR 487.27 | 1 Piece(s) | 1 Day(s) |
Loading...
| Application | SSR | Terminal shape | Screw Fastening | Safety standards | CE / UL / CSA |
|---|---|---|---|---|---|
| Dimension height(mm) | 90 | Dimension width(mm) | 90 | Dimension depth(mm) | 100 |
| Insulation method | Phototriac | Operation Indicator Lamp | Available | Input rated voltage(V) | DC 12–24 |
| Function | 0.75kW (4.8A)/200 to 220 VAC |
Please check the type/dimensions/specifications of the part G3J-205BL DC12-24 in the Single Function Type G3J series.

How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy