Transformers(Secondary voltage:AC100-110)

The MISUMI eCatalog has single-phase/single-winding, single-phase/multiple-winding, and three-phase/multiple-winding transformers, but also transformers with capacities from 0.0009 kVA to 200 kVA.

[Transformers]
Transformers are also called voltage transforming devices. They convert AC voltages to different voltages using electromagnetic induction. Voltage transformers consist of multiple magnetically coupled coils. The conductor used for the coil is called the winding.
When there are two coils, the coil on the input side is called the primary coil and the coil on the output side is called the secondary coil. When alternating current flows in the primary coil, a time-varying magnetic field is generated, transmitting power to the secondary coil coupled via mutual inductance, when the energy is converted to current again and output.
Changing the voltage by means of a transformer is called transformation. When the voltage is raised it is called a step-up transformer, and when the voltage is lowered it is called a step-down transformer.
Days to Ship
  • All
  • 1 Day(s) or Less
  • 2 Day(s) or Less
  • 3 Day(s) or Less
  • 7 Day(s) or Less
  1. 1
Brand
Product Series
CAD
Days to Ship
Number of phases/winding
Capacity(kVA)
Primary voltage(V)
Secondary voltage(V)
Shield presence
Insulation type
Input/output terminal shape
With/without Case
Dimension vertical(mm)
Dimension width(mm)
Dimension depth(mm)

    Series with SC21-ELED

      PC41-E series

      Brand

      SWALLOW ELECTRIC

      SWALLOW ELECTRIC

      Product Series

      Series with SC21-ELED

      PC41-E series

      CAD
      • 2D
      • 2D
      Days to Ship 7 Day(s) or more 3 Day(s) or more
      Number of phases/windingSingle-phase/Double-windingSingle-phase/Double-winding
      Capacity(kVA)0.750.75
      Primary voltage(V)AC200-220AC380-400-440
      Secondary voltage(V)AC100-110AC100-110
      Shield presenceAvailableAvailable
      Insulation typeE TypeE Type
      Input/output terminal shapeUp screw type terminal blockUp screw type terminal block
      With/without CaseNANA
      Dimension vertical(mm)150145
      Dimension width(mm)146146
      Dimension depth(mm)145150