(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 9:00 19/4/2026 to 7:00 (MYT) 20/4/2026. We apologize for the inconvenience.
  • [Notice] Japan & China Golden Week holidays will start from 29 April to 6 May 2026. Kindly expect longer response from suppliers and possible delivery delay due to high volume of shipments after holiday. Early order placement is recommended. More details
  • [Announcement] MISUMI Malaysia website new user interface. Clearer navigation, easy product search and more. Explore now! May contact us at (60) 3 7890 6399 for any inquiries.

KVC36SB UL Standard with Shield (KVC36SB-0.3-10P-56)

KVC36SB UL Standard with Shield KVC36SB-0.3-10P-56

With 150 V Standard Shield for Signals

  • c-UL
  • VW-1
  • FT-1
  • ULAWM
  • Oil-Resistant
  • Strand Wire
  • Single Shield
  • Twisted Pair
  • Less than 100 V

· 1.5P sizes are not twisted pairs.
· This product is compatible with "UL Traceability Program / Processed Wire". (c-UL is not compatible)
* For cables in stock, please keep in mind that because we cut them to the specified size, they cannot be canceled or returned.
* Color and softness may vary slightly due to manufacturer changes.

Electrical Appliance and Material Safety Law certificate is not obtained.

PDF

Part Number

Configured Part Number is shown.

KVC36SB-0.3-10P-56

Specifications

KVC36SB UL Standard with Shield:Related Image

Model NumberSection Area
(mm2)
Number of Pairs *3
1P = 2 Cores
Total Length
or
Specified Length
Model NumberSection Area
(mm2)
Number of Pairs *3
1P = 2 Cores
Total Length
or
Specified Length
KVC36SB
(Twisted Pair Type)
0.21P1
~
100
(Specify 1 m
Increment)
1.5P (3-Core)
2P
3P
4P
5P
6P
7P
8P
10P
12P
15P
20P
25P
30P
32P
0.31P
1.5P (3-Core)
2P
3P
4P
5P
6P
7P
8P
10P
12P
15P
20P

More Information


Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
* For the latest information regarding standard unit price, quantity slide unit price, shipment days, etc., refer to the Misumi VONA e-catalog.
*1 Stock products are indicated with T or A in the price column at right.
*2 All unit prices above are per meter.
Unit Price Calculation Method [Formula: Last digits of model number (m) x unit price per meter above]
*3 Check the indications for number of cores, pair number, core / pair number, and pair number / core when ordering.

KVC36SB UL Standard with Shield:Related Image
KVC36SB UL Standard with Shield:Related Image
KVC36SB UL Standard with Shield:Related Image

Specifications
Model NumberSection Area
( mm2) *2
Number of Pairs *1
1P = 2 Cores
AWG
Estimate* 2
Twisted
Structure
(See Figure)
Number of
Wire Cores
Finished *5
Outer Diameter
(mm)
Approximate
Mass
kg/km
Electrical PropertiesConductorInsulationWire Core
Outer Diameter
Approx. (mm)
SheathSpecification
Allowable Current
A (30°C)* 3
Conductor Resistance
Ω / km (20°C)
Insulation Properties
MΩkm (20°C)
Withstand Voltage
V / Min
Structure
Strands / mm
Outer Diameter
Approx. (mm)
Plating *4Thickness
(mm)
Material *4Thickness
(mm)
Material *4
KVC36SB
(Twisted Pair Type)
0.21P25Twisted Pair23.9215113 or less50 or more1500
AC
7/0.180.54Tin0.25PVC1.050.5PVCULAWM2936
c-UL
1.5P (3-Core)34.12440.5
2P45.74040.85ULAWM2576
c-UL
3P65.94540.85
4P86.45530.85
5P106.86530.85
6P127.57530.9
7P147.78030.9
8P168.29030.9
10P209.0 10520.9
12P249.111521.0
15P3010.014021.0
20P4011.517021.0
25P5012.520521.05
30P6014.0 24521.15
32P6414.0 25521.15
0.31P2324.628762.3 or less50 or more1500
AC
12/0.180.7N/A0.31.30.6ULAWM2936
c-UL
1.5P (3-Core)34.83560.6
2P46.25060.85ULAWM2576
c-UL
3P67.17051.0
4P87.88551.0
5P108.510041.0
6P129.311541.1
7P149.512041.1
8P1610.0 13541.2
10P2011.517041.3
12P2412.0 18531.3
15P3013.0 21531.3
20P4014.527531.4


*1 Please note that when the indicated Core / Pair is 1P (1PS), the number of wire cores will be "x 2-core".
*2 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*3 The value of allowable current is to be used only as a reference value and is not guaranteed.
*4 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material;
P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other
*5 For the outer diameter size of cables, wire sheath (coat), etc., refer to "Finished Outer Diameter" in the table above.    

Current Reduction Factor
Ambient Temperature (°C)30405060708090100
Current Reduction Factor1.000.930.860.770.680.580.450.26
Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current value when the ambient temperature is 40°C, 0.2mm21 P: 5 x 0.93 = 4.65 (A)

KVC36SB UL Standard with Shield:Related Image

Wire Core Identification
Pair No.1234567891011
Insulator ColorBlackBlackRedRedGreenGreenYellowYellowBrownBrownBlueBlueGrayGrayOrangeOrangePurplePurpleLight GreenLight GreenPinkPink
Color of Identification Line-White-White-White-White-White-White-White-White-White-White-White
Pair No.1213141516171819202122
Insulator ColorLight BlueLight BlueWhiteWhiteGreenGreenYellowYellowBrownBrownBlueBlueGrayGrayOrangeOrangePurplePurpleLight GreenLight GreenPinkPink
Color of Identification Line-White-BlackBlackRedBlackRedBlackRedBlackRedBlackRedBlackRedBlackRedBlackRedBlackRed
Pair No.23242526272829303132 
Insulator ColorLight BlueLight BlueRedRedBlackBlackWhiteWhiteBrownBrownBlueBlueGrayGrayOrangeOrangePurplePurpleLight GreenLight Green
Color of Identification LineBlackRedBlackGreenGreenYellowGreenYellowGreenYellowGreenYellowGreenYellowGreenYellowGreenYellowGreenYellow
* Wire core identification for 1.5 number of pairs (3-core strand)
Pair No.1.5
Insulator ColorBlackBlackRed
Color of Identification Line-White-
 
KVC36SB UL Standard with Shield:Related Image
Part Number
KVC36SB-0.3-10P-56
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOverall Length
(m)
Conductor Cross Section
(mm2)
AWG size
(AWG)
Logarithm Finished outer diameter
(mm)

MYR 4,146.84

1 Piece(s) 2 Day(s) or more 560.32310P11.5

Loading...

  1. 1

Basic Information

Rated Voltage 150V Shield Present Properties Oil resistance
Representative Standard UL / CSA(c-UL) Sheath (outer coating) color Black Sheath (outer coating) material PVC
Insulation body materials PVC Power supply/signal Dual use Other properties Pliability / Noise Resistance

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7960 8499 / FAX:(60) 3 7960 7499
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)